SciAps reveNIR

The lightest and fastest handheld VIS-NIR on the market

The NEW SciAps handheld Vis-NIR (Near-Infrared Spectroscopy) analyzer is a game-changing portable instrument that delivers unmatched performance in mineral reconnaissance and exploration. 

Designed for geologists and exploration teams working in the most remote locations, the reveNIR offers precise and efficient mineralogical analysis in the field, enabling better decision-making and faster progress.

Looking for more information?

To request a quote, more information or download a brochure select an option below.

Introducing the new SciAps reveNIR

The discontinuation of the ASD Halo left a significant gap in the market - one that existing solutions couldn’t fill. In response, SciAps has developed a new handheld Vis-NIR analyzer designed to meet this critical need. 

Compact, powerful, and built with cutting-edge technology, the SciAps reveNIR analyzer ensures you have the precision and portability you need for accurate analysis in the field.

How it works

The SciAps reveNIR analyzes reflectance spectra to detect transitions between different mineral types. These transitions indicate significant changes in mineralogy, helping geologists determine proximity to ore bodies. 

With the reveNIR, teams can detect mineral changes in real time and adjust drilling strategies as needed.

Key features

  • Portability

    Lightweight and compact, the SciAps reveNIR handheld analyzer is optimized for use in challenging terrains. Under 4.5 lbs with the battery, the reveNIR is 2 lbs lighter and 50% smaller than ASD Halo. From mountainous areas to remote mines accessible only by helicopter or small plane, the reveNIR’s design ensures ease of transport and use.

  • On-site mineral identification

    The SciAps reveNIR detects key minerals like Epidote, Calcite, Chlorite, Kaolinite, Halloysite, Montmorillonite, Muscovite, Illite, Smectites, Dickite, Hematite, Goethite, Rectorite, and Rare Earth Oxides, among others. These are essential for vectoring in on ore bodies and guiding drill operations.

  • Versatility

    Perfect for reconnaissance, core logging, rock chip analysis, and expanding mapping areas. The SciAps reveNIR allows users to analyze outcrops, measure various positions, and assess the mineralogy of geological formations effortlessly.

  • Rapid decision-making

    With real-time mineral spectra analysis, the SciAps reveNIR eliminates the need for lab delays, allowing geologists to adjust their exploration strategies instantly.

Reflectance spectra analysis

The SciAps reveNIR records reflectance spectra to predict mineral composition of samples - a critical tool for understanding geological formations and identifying pathfinder minerals. 

  • Key spectral range from 350 to 2510 nm
  • Mineral spectral library of 250 exploration minerals included
  • Capability for user spectral additions/subtractions and converting publicly available USGS SpecLib 7a downloads
  • Real-time Spectral Scalars calculations of Al-OH, ISM (Illite Spectral Maturity), Mg-OH, and Fe3t, indicating crystallinity, composition and/or geothermal conditions, as additional vectors to potential mineralization

Applications

Early-stage reconnaissance

Analyze surface samples, dig around outcroppings, and assess rock formations in areas without easy access. The reveNIR provides critical insights to determine if further exploration is worthwhile.

Core logging and drill guidance

Identify alteration minerals and pathfinder minerals in drill core samples to direct drilling operations effectively and maximize resource extraction.

Exploration mapping

Expand the understanding of geological formations by measuring multiple positions on outcrops and assessing mineralogical changes across the landscape.

Specification

Weight 2.1 kg with battery
Dimensions 27.2 x 27 x 8.9 cm
Excitation source Halogen bulb
Detector
VIS1: CCD array (>2000 pixels)
NIR1: InGaAs array (256 pixels)
NIR2: Extended InGaAs (256 pixels)
Applications Mining
Temperature range 5 °C to 40 °C
Analytical range 350 nm - 2500 nm
Processing electronics and host processor
Powerful quad Arm® Cortex®-A53 processor with a Neural Processing Unit (NPU) operating at up to 2.3 TOPS
Power
On-board rechargeable Li-ion battery, rechargeable inside device or with external charger, AC power, hot-swap capability (60 s max swap time)
Display
3.5” color touchscreen smartphone type display – PowerVR SGX540 3D graphics
Data Transfer
USB-C, Bluetooth, Wi-Fi, GPS calibration
Calibration type Built-in mineral library
Calibration check
The unit is wavelength calibrated. During regular operation, a white external reference calibration is needed every 30-60 minutes when the unit is warmed up. The unit’s calibration is automatically checked against its internal references to correct fast drift.
Security Password protected usage (user level) and internal settings (admin)
Camera Two 5-megapixel cameras
Regulatory testing CE, RoHS

Why choose ‍SciAps reveNIR?

  • Fast Results: No waiting weeks or months for lab data
  • Enhanced Exploration Efficiency: Identify valuable resources sooner
  • Unparalleled Portability: Navigate challenging environments with ease
  • Versatile Technology: Use alongside portable XRF for comprehensive exploration capabilities

The reveNIR isn’t just a tool; it’s a vital partner in mineral exploration, helping you make informed decisions and optimize resource extraction. 

Add the reveNIR to your exploration toolkit and experience the difference.

Specification highlights

  • Spectral Range: 350 to 2510 nm
  • Spectrometer Resolution: VIS1: 3 nm midrange, NIR1:8 nm, NIR2: 8 nm
  • Applications: Supports multiple NIR libraries plus custom libraries
  • Weight: 4.5 lbs with battery (50% smaller than original Halo)
  • Dust and Water Resistance: IP54 Rated
  • Mounting: Industrial version for core-scan mounting
  • Battery Life: Up to 6 hours of continuous use
  • Wireless: On-board WiFi, GPS, Bluetooth
  • Storage and Reporting: On display, stored on unit, download to PC, cloud
  • Cloud: Cloud Connectivity for external libraries and real-time results

Why portability matters

Early-stage exploration sites are often in extremely remote locations, far from airports or roads. Getting to these sites may require helicopters or climbing steep terrains, where bulky equipment is impractical.

The reveNIR’s compact design makes it ideal for such environments, ensuring geologists can focus on their work without being weighed down by heavy tools.

Mineral analysis with reveNIR

Geologists rely on Vis-NIR to detect minerals that indicate proximity to ore bodies. These include clays, alteration minerals, and other pathfinder minerals that help vector drilling operations towards valuable resources.

The SciAps reveNIR’s Vis-NIR technology provides accurate, real-time data on:

  • Epidote
  • Calcite
  • Chlorite
  • Kaolinite
  • Halloysite
  • Montmorillonite
  • Muscovite
  • Illite
  • Smectites
  • Dickite
  • Hematite
  • Goethite
  • Rectorite
  • Rare Earth Oxides

Unlike XRF, which is primarily used to track elemental ore grade, especially metals concentration, the reveNIR excels at identifying chemically complex minerals critical for exploration. This complementary use of technologies ensures comprehensive data for decision-making.

Complementary tool for geotechs and geologists

The SciAps reveNIR is the perfect addition to geologists’ exploration toolbelt for its speed, accuracy, and reliability. It complements visual observations, XRF analysis, and laboratory assays. 

Bridge the gap between fieldwork and lab results with the reveNIR, empowering teams to make faster, data-driven decisions in time-critical projects.

Manuals

Title Version Date Download
{{ row.pageTitle }} {{ row.softwareVersion }} {{ row.date }} Download

Sorry, no manuals are available for this product

Software

Title Version Date Download
{{ row.title }} {{ row.softwareVersion }} {{ row.date }} Download

Sorry, no software downloads are available for this product

Taking NIR to the next level.

Taking NIR to the next level.

The lightest, fastest handheld VIS-NIR on the market. Revolutionise your mineral exploration.

Contact sales Request a quote Request a demo