The SciAps X-Series is the world’s lightest, smallest, fastest, high precision family of handheld XRF analyzers. With the newest models weighing under 1.3kg, and lightning fast, they can be used all day long without fatigue.
Looking for more information?
To request a quote, more information or download a brochure select an option below.
2 cameras for precise targeting, photo-documenting, reading QR and bar codes
Lightweight, balanced, ergonomic, free-standing design
Detector Protector Technology (DPT) safeguards the detector with an advanced high-strength window
Global connectivity – monitor testing, check quality, print reports in real time
Lowest service costs in the business
Intuitive Android operating system
Explore our industry-leading handheld XRF instruments.
US & Canada customers can now purchase the X-5 and X-50 directly from MyStore!
The totally re-engineered X-200 and X-50 are the lowest-priced XRF guns on the market, yet still offer best-in-class analytical and speed performance, with all the accuracy and throughput of the X-5 Series.
Now with improved heat dissipation, reduced weight, and new user interface.
The standard element packages for the various models and applications are shown in the table below. Require other elements? Just ask! We add or substitute elements frequently for specific applications.
| Application | Beam 1 (40 kV) | Beam 2 (10 kV) | Beam 3 (50 kV) |
|---|---|---|---|
| Mining | Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Sr, Rb, Zr, Nb, Mo, W, Ta, Au, Hg, Pb, Bi, U | Mg, Al, Si, P, S, K, Ca | Ag, Sn, Sb, Ba |
| Soil | Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Sr, Rb, Zr, Mo, W, Tl, Hg, Pb, Bi | Mg, Al, Si, P, S | Ag, Cd, Sn, Sb, Ba |
| Alloy | Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Y, Zr, Nb, Mo, W, Ta, Hf, Re, Au, Pb, Bi, Ru, Pd, Ag, Cd, Sn, Sb | Mg, Al, Si, P, S | N/A |
| Precious metals | Ti, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, W, Au, Ge, Ir, Pt, Au, Pb, Bi, Zr, Mo, Ru, Rh, Pd, Ag, Cd, In, Sn, Sb | N/A | N/A |
| Application | Beam 1 (40 kV) | Beam 2 (10 kV) | Beam 3 (50 kV) |
|---|---|---|---|
| Mining | Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Sr, Rb, Zr, Nb, Mo, W, Ta, Au, Hg, Pb, Bi, U, Ag, Sn, Sb | S, K, Ca | N/A |
| Soil | Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Sr, Rb, Zr, Mo, W, Tl, Hg, Pb, Bi, Ag, Cd, Sn, Sb | N/A | N/A |
| Alloy | Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Y, Zr, Nb, Mo, W, Ta, Hf, Re, Au, Pb, Bi, Ru, Pd, Ag, Cd, Sn, Sb | N/A | N/A |
| Precious metals | Ti, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, W, Au, Ge, Ir, Pt, Au, Pb, Bi, Zr, Mo, Ru, Rh, Pd, Ag, Cd, In, Sn, Sb | N/A | N/A |
| Weight | 1.4 kg with battery |
|---|---|
| Dimensions | 238 x 283 x 84 mm |
| Power | On board rechargeable Li-ion battery, rechargeable inside device or with external charger, AC power, hot-swap capability (60s max swap time) |
| Display | 3.5 inch (89 mm) color capacitive touchscreen, 400 MHz Qualcomm Adreno 306 2D/3D graphics accelerator |
| Data Transfer | Wi-Fi, Bluetooth, USB connectivity to most devices, including SciAps Profile Builder PC software; GPS capable; Cloud data management options available |
| Excitation source | 5 W X-ray tube. 50 kV max, 200 uA max, Rh or Au anode depending on application |
| Detector | 20mm2 silicon drift detector (active area), <140eV resolution FWHM at 5.95 Mn K-alpha line |
| X-Ray filtering | 6 position filter wheel for beam optimization |
| Processing electronics and host processor | 1.2GHz ARM Cortex-A53 quad-core, 64/32-bit
RAM: 2GB LPDDR3 Storage: 16GB eMMC |
| Pulse processor | 14-bit ADC with digitization rate of 80 MSPS 8K channel MCA USB 2.0 for high-speed data transfer to host processor
Digital Filtering implemented in FPGA for high throughput pulse processing 50 nS – 24 uS peaking time |
| Calibration type | Fundamental parameters; For Geochem and Environmental Soil Apps, users may also choose “Compton Normalization” method and/ or use empirically derived calibrations |
| Temperature range | -12 C to 54 C at 25% duty cycle |
| Security | Password-protected usage (user level) and internal settings (admin) |
| Regulatory testing | CE, RoHS, USFDA registered, Canada RED Act |
| Weight | 1.4 kg with battery |
|---|---|
| Dimensions | 238 x 283 x 84 mm |
| Power | On board rechargeable Li-ion battery, rechargeable inside device or with external charger, AC power, hot-swap capability (60s max swap time) |
| Display | 3.5 inch (88.9 mm) color capacitive touchscreen; 400 MHz Qualcomm Adreno 306 2D/3D graphics accelerator |
| Data Transfer | Wifi, Bluetooth, USB
Connectivity to most devices, including SciAps Profile Builder PC software |
| Excitation source | 4 W, 40 kv Rh on alloys; 50kv Au on other apps |
| Detector | 7 mm2 SDD, silicon drift detector, (active area), 170 eV resolution FWHMat 5.95 Mn K-alpha line |
| X-Ray filtering | Single primary beam filter for alloy, mining, precious metals
Multiple filters for soil, RoHS, car catalysts and some other apps |
| Processing electronics and host processor | 1.2 GHz quad ARM Cortex A53 64/32-bit
RAM: 2 GB LP-DDR3 Storage: 16 GB eMMC (storage) |
| Pulse processor | 12-bit with digitization rate of 80 MSPS 8K channel MCA USB 2.0 for high-speed data transfer to host processor
Digital filtering implemented in FPGA for high throughput pulse processing, 20 nS - 24 uS peaking time |
| Calibration type | Fundamental parameters |
| Calibration check | External 316 stainless check standard for calibration verification and energy scale validation |
| Temperature range | -12°C to 54°C at 25% duty cycle |
| Security | Password-protected usage (user level) and internal settings (admin) |
| Regulatory testing | CE, RoHS, USFDA registered, Canada RED Act |
The X-550 sets a new performance standard for handheld XRF. Weighing 1.3 kg with the battery, it’s the smallest, lightest, fastest XRF analyzer on the market. It’s fast on all alloys and as good on aluminums as it is on high temps for the scrap market, and it comes with fully loaded apps for NDT (Residuals, Sulfidic Corrosion, Alloy).
The X-550 uses the industry’s most powerful X-ray tube, operating up to 3x the power in the Beam 2 setting compared to the SciAps X-505 and any other handheld XRF analyzers. The unique geometry and tube power optimize performance for low atomic number measurement applications including sulfidic corrosion (low Si), phosphorus and sulfur, and aluminum alloys, as well as for residuals analysis per API 751 and 5L specifications.
Premium performance begins with the most advanced handheld XRF technology available, led by a 55 kV X-ray tube for extra-low detection limits on key elements like Ag, Cd, Sn, Sb, and Ba.
Up to three automated beam settings provide optimal performance across the entire periodic table from Mg to U.
All in a rugged instrument with state-of-the-art software and outstanding thermal dissipation.
What’s the difference between the premium X-550 and X-505?
The answer is simple: Speed on low atomic number elements such as Mg, Al, Si, P and S.
When the X-550 runs at about 3x the X-ray power in the “Beam 2” setting (also known as the low voltage setting) compared to the X-505 or other handheld XRF analyzers, the measured intensities from Mg, Al, Si, P and S (plus K, Ca and Cl in other apps) are 3x higher, producing 3x faster measurements with the X-550.
Want the accuracy and throughput of the premium models, but in a lower-priced series of analyzers? Then consider the totally re-engineered “value” series, with improved heat dissipation, reduced weight, new user-interface. All internal electronics now use less power and operate at higher temperatures—no drift or shutdown.
The SciAps X-200 offers comparable speed and precision to top-of-the-line competing brands, but at a lower price point, in a smaller, lighter package.
The X-200 silicon drift-detector (SDD) model is competitively priced for every performance requirement. Only slightly heavier than the X-505/550 platform, the X-200 still provides industry-leading speed and precision - it is the value version of the X-505.
The completely re-engineered SciAps X-50 XRF analyzer is the highest performing on the market featuring a cost-effective SDD detector.
It offers best-in-class analytical performance and speed for its detector platform, operating at rates 2x or higher than other brands.
The X-50 is our most economical model, offering great basic analysis of transition and heavy metals.
The SciAps X-5 is an excellent choice for conducting basic analysis of transition and heavy metals.
Designed for users who do not require measurements of Mg, Al, Si, S, or P in alloys or other materials.
For these users, we’ve re-engineered this classic technology and equipped it with more features for many applications at a great value.
Alloy and scrap: For many NDT/PMI jobs that require verification of low alloy, Cr/Mo steels, stainless and corrosion-resistant alloys, the X-5 often delivers excellent performance. Alloy applications include sorting stainless steels, high temp alloys and red metals.
And more: The X-5 is also available for precious metals, RoHS, soil, mining, car catalysts, industrial lead paint and other user-customizable applications.
| Title | Version | Date | Download |
|---|---|---|---|
| {{ row.pageTitle }} | {{ row.softwareVersion }} | {{ row.date }} | Download |
Sorry, no manuals are available for this product
| Title | Version | Date | Download |
|---|---|---|---|
| {{ row.title }} | {{ row.softwareVersion }} | {{ row.date }} | Download |
Sorry, no software downloads are available for this product
The world’s lightest, smallest, fastest, high precision family of XRF analyzers. Advance your analysis in the field.