Delivers high throughput and sensitivity with low sample consumption, in an integrated platform built for productivity.
Differential scanning calorimeters
Unmatched sensitivity. Proven reliability. Differential scanning calorimetry for biologics stability testing. Reproducible results with less sample and less effort, every time.
Working with costly, limited biomolecules shouldn't mean compromising on data quality or analysis speed. MicroCal PEAQ-DSC instruments - including MicroCal PEAQ DSC and MicroCal PEAQ-DSC Automated – eliminate this trade-off, delivering precise, reproducible thermal stability profiles using a fraction of the sample volume, with no labeling and minimal assay development required.
Get objective, reproducible data you can trust.
Maximize productivity with smarter workflows and walk-away automation.
Built for the demands of the regulated biopharmaceutical environment.
Both MicroCal PEAQ-DSC and MicroCal PEAQ-DSC Automated have the same PEAQ-DSC software and deliver the same gold-standard sensitivity. For labs that already have MicroCal PEAQ-DSC and want to expand their throughput or sample volume capabilities, there is a clear upgrade path to the MicroCal PEAQ-DSC Automated system.
Delivers high throughput and sensitivity with low sample consumption, in an integrated platform built for productivity.
A manual instrument delivering highly sensitive, easy-to-use microcalorimetry, reducing the time and cost of stability testing and comparability analysis.
| Technology | Differential Scanning Calorimetry |
|---|---|
| Measurement type | Temperature midpoint TM
Enthalpy ΔH Heat capacity change ΔCP |
| Maximum scan rate | 240 °C/h |
| Reverse scanning | Yes |
| Multiple feedback modes | Yes (passive, high gain, low gain) |
| Temperature range | 2 - 130 °C 1,2 |
| Cell material | Capillary / Tantalum |
|---|---|
| Cell volume | 130 μL |
| Minimum sample volume | MicroCal PEAQ-DSC Automated: 325 μL
MicroCal PEAQ-DSC: 250 μL (manual filling) |
| Typical sample concentration | 0.01–10 mg/mL |
| Sample capacity | MicroCal PEAQ-DSC Automated: 288 (6 × 96-well plates)
MicroCal PEAQ-DSC: n/a |
| Sample throughput | MicroCal PEAQ-DSC Automated: ≤50 samples/day
MicroCal PEAQ-DSC: ≤6 samples/8h |
| Sample storage temperature range | MicroCal PEAQ-DSC Automated: 4 °C to 40 °C
MicroCal PEAQ-DSC: n/a |
| Cleaning routines | MicroCal PEAQ-DSC Automated: 3 pre-programmed routines; water and detergent
MicroCal PEAQ-DSC: Manual cleaning device; water and detergent |
| Noise | 0.05 μCal/°C 1 |
|---|---|
| Baseline repeatability | 1 μCal/°C 1 |
| Response time | 5s 1 |
| Measurement repeatability | 0.2 μCal/°C 4 |
| Measurement reproducibility | <0.08 °C St.Dev. TM, <2% RSD ΔH |
| System reproducibility | <0.1 °C St.Dev. TM, <5% RSD ΔH |
| Binding constant sensitivity | Up to 1020 M-1 |
| 21 CFR part 11 | 21 CFR compliance ready, with PEAQ-Compliance option |
|---|---|
| Network ready | Yes, with email alerts |
| Power | MicroCal PEAQ-DSC Automated: 100–240V AC, 50/60Hz, 70W (cell), 400W max (autosampler)
MicroCal PEAQ-DSC: 100–240V AC, 50/60Hz, 70W (cell) |
|---|---|
| Operating temperature (°C) | 10–28 °C |
| Storage temperature | -20 to 50 °C |
| Humidity | 10–70% non-condensing (10–90% storage) |
| Ingress Protection (IP) rating | IP21 |
| Dimensions | MicroCal PEAQ-DSC Automated: 101 × 70 × 68 cm
MicroCal PEAQ-DSC: 20 × 19 × 44 cm |
| Weight | MicroCal PEAQ-DSC Automated: Approx. 25 kg
MicroCal PEAQ-DSC: 8.2 kg |
| Certification | CE, EMC (EN61326 series, FCC, ICES, VCCI), ISO9001:2008 |
| Notes | 1 Typical results for ribonuclease (RNase) in 50 mM KAc buffer at pH 5.5, at 60°C/h with high feedback
2 Range may be extended down to -10°C upon request 3 Sample dependent 4 Rescans of a stable buffer 5 Using ribonuclease (RNase) |
|---|
PEAQ-Compliance brings 21 CFR Part 11 and Annex 11 tools to your MicroCal PEAQ-DSC, with full audit trails and electronic signatures.
Compliance
MicroCal PEAQ-DSC and MicroCal PEAQ-DSC Automated both operate on our powerful MicroCal PEAQ-DSC software, which supports the following four specialist modules. Click the cards below to learn more.
PEAQ-Performance automatically ensures that your instrument is performing at an optimal level, building confidence in the reliability and reproducibility of your data without wasting samples on replicate analyses.
Checks can be built into experimental sets and are analyzed automatically against expected results, with an alert raised on failure – giving you the chance to stop a run before losing time or sample.
PEAQ-Smart includes embedded videos covering both experimental design and instrument maintenance, plus a built-in report designer. SOP-Builder guides and accelerates experimental set-up, including rescans and downscanning for reversible denaturation studies.
PEAQ-Finder, included within PEAQ-Smart, automates TM determination across multiple thermograms, with automatic peak selection that resolves overlapping transitions and even minor shoulders, revealing peaks that were previously undetectable.
PEAQ-Compliance controls electronic records via an audit trail and logs key events such as record creation and modification. It enables robust method development and transfer, with the support of 21 CFR Part 11 and Annex 11 compliance tools, and full lifecycle documentation.
PEAQ-Compare assesses several DSC parameters to determine and rank-order comparability, and provides detailed information on residual data.
MicroCal PEAQ-DSC works with most soluble biomolecules, from mAbs and vaccines to gene therapies and delivery vectors – supporting stability studies from early formulation through manufacturing.
Validates biosimilars against reference products and confirms consistency between batches after manufacturing or process changes – essential for pharma and biopharma QC and regulatory teams.
Supports formulation and stability screening for vaccines and gene therapeutics through development and manufacturing.
Used in pharma for delivery-vector formulation work, and in academic research investigating drug delivery mechanisms.
Rapidly ranks ligand affinities to a protein target and characterizes a drug's target, supporting small molecule development and manufacture.
Sensitive, reproducible analysis of protein folding and unfolding. Built for academic research and publication-grade reproducibility.
Protect your proteins with global support from our expert application scientists. Every MicroCal PEAQ-DSC comes with access to service agreements that suit your operations, expert application consultancy, manuals, software and training.
Maintenance
MicroCal PEAQ-DSC delivers precision thermal stability characterization, while using up less of your valuable time and sample.
Benefit from: