Mastersizer 2000

Approaching a quarter of a century after its launch, the groundbreaking Mastersizer 2000 will reach the end of its formal support life in April 2022. It’s therefore essential to plan your system upgrade and method transfers now.

Its successor, the Mastersizer 3000, packs even more laser diffraction know-how into a compact, easy-to-use instrument that delivers class-leading particle sizing performance.

Don’t delay. Book your upgrade consultation today.

Looking for more information?

To request a quote, more information or download a brochure select an option below.

Manuals

Title Version Date Product Download
{{ row.title }} {{ row.softwareVersion }} {{ row.date }}
{{ product }}
Download

Sorry, no manuals are available for this product

Software

Title Version Date Product Download
{{ row.title }} {{ row.softwareVersion }} {{ row.date }}
{{p}}
Download

Sorry, no software downloads are available for this product

Accessories

Wet dispersion units

Hydro 2000G

Large volume automated wet dispersion accessory.

The Hydro 2000G is a fully automated large volume wet sample dispersion unit. It is most suitable for QC applications where representative sampling is important, as well as the measurement of polydisperse samples with very broad particle size distributions.

Hydro 2000MU

Large volume manual wet dispersion accessory

The Hydro 2000MU is a large volume manual wet sample dispersion unit designed for use with standard laboratory beakers.

Hydro 2000S

Small volume automated wet dispersion accessory

The Hydro 2000S is a fully automated small volume wet sample dispersion unit. It is most suitable for applications where the amount of sample or volume of dispersant needs to be minimized.

Hydro SM

Small volume entry level wet dispersion unit

The Hydro SM is a cost effective wet sample dispersion unit designed for measuring samples in non-aqueous dispersants where solvent usage needs to be minimized.

Hydro 2000µP

Small volume wet dispersion accessory

The Hydro 2000µP is a small volume wet sample dispersion unit designed specifically for measuring small quantities of high value or hazardous materials such as pharmaceutical actives.

Autosampler 2000

High throughput particle size measurements.

For laboratories with a high sample throughput requirement, the Autosampler 2000 delivers fully automated particle size distribution measurements for the Mastersizer 2000. Automatic preparation and dispersion of samples gives true intervention-free operation to free key personnel for other tasks.

Dry dispersion units

Scirocco 2000

Dry powder dispersion

The Scirocco 2000 is an automated dry powder dispersion unit for the Mastersizer 2000 particle size analyzer.

Events and training

All events

Service and Support

Protect your investment and ensure optimized performance at all times with Malvern Panalytical's service plans.

When you purchase a Malvern Panalytical product we understand that this is just the first stage of a working relationship that will last for the lifetime of the instrument. Depending on your needs, Malvern Panalytical will provide the support for your business.

Help Desk

  • Telephone and email support.
  • Operators who take responsibility for your call and ensure your query is answered. 

Training

  • User training events
  • E-learning

Software downloads

Malvern Panalytical's service options- choose the right plan for you:

PlatinumMedal

Malvern Panalytical Platinum Plan

For laboratories where maximizing instrument up-time is critical to its daily performance. Our highest level of response and the 'all inclusive' price plan takes care of those unexpected repair bills should the unfortunate occur.

GoldMedal

Malvern Panalytical Gold Plan

Enhance your laboratory productivity by maintaining instrument efficiency. Still receive that priority response, combined with specialist technical and software support, we'll keep your instrument performance on track to deliver.

BronzeMedal

Malvern Panalytical Bronze Visit

For laboratories looking to optimize instrument performance, regular preventative maintenance is essential.

Platinum PlanGold PlanBronze Visit
Annual PM/PV Test
yes
yes
no
Telephone / Email Support
yes
yes
no
Priority Response
yes
yes
no
Emergency Breakdown visits*
yes
yes
no
Parts Included
yes
no
no
E-Learning**
yes
yes
no
Technical & Software Support
yes
yes
yes
IQ/OQ (Pharma)***
yes
yes
yes

*including labour & travel costs** Platinum 2 places per contract term, Gold 1 place per contract term***available at an additional cost

Contact support