Access support to accelerate your scientific discovery with grants of up to $25K, $50K, $75K or 50% off. Apply to our Academic Grant Program now

Apply to our Academic Grant Program now

Zetasizer Lab

Classic side scatter particle size and zeta potential analyzer with enhanced capabilities

  • Traditional 90-degree side-scatter size measurements 
  • Adaptive Correlation, M3-PALS, and constant current zeta mode 
  • Extended size range analysis when used with ZSU1002 capillary cell
  • ZS Xplorer analytical software offers instant feedback on data quality, and guidance on how to improve your results

Select a model:

Looking for more information?

To request a quote, more information or download a brochure select an option below.

Overview

The Zetasizer Lab is the perfect entry-level system. The Zetasizer Lab offers traditional 90-degree side-scatter size measurements but still offers enhanced features. 

It incorporates Adaptive Correlation, M3-PALS and constant current zeta mode as well as our extended size range analysis when used with ZSU1002 capillary cell. 

The Zetasizer Lab also ships with ZS Xplorer, our easy-to-use analytical software. ZS Xplorer offers instant feedback on data quality, and guidance on how to improve your results.

Available in Blue Label and Red Label variants:

  • Choose Blue Label for routine sample investigation such as metallic colloids, metal oxides and pigments
  • Choose Red Label for more challenging sample types, such as proteins, surfactant solutions and low solid content samples
Om_logo.png

 Works with OmniTrust: Malvern Panalytical's compliance solution for the regulated environment

Features

  • DLS analysis : particle size measurements from 0.3 nm to 10 μm

  • Zeta potential of nanoparticles and colloids using M3-PALS analysis and constant current zeta mode

  • Molecular weight using Static Light Scattering at 90°

  • Supports use of Low Volume Disposable Capillary Cell for size measurements in sample volumes as low as 3 μL

  • Extended size range analysis offers improved accuracy for particle sizes above 1 μm, and indicative results above 10 μm (using ZSU1002 Low Volume Disposable Sizing Cell)

  • On-site upgradeability to either Zetasizer Pro or Zetasizer Ultra models

Which Zetasizer is right for me?

Zetasizer Ultra Zetasizer Pro Zetasizer Lab
Size Measurement Principle Non-Invasive Back Scatter (NIBS)
Dynamic Light Scattering
Dynamic Light Scattering (90° and 13°)
Multi-Angle Dynamic Light Scattering (MADLS®)
Non-Invasive Back Scatter (NIBS)
Dynamic Light Scattering
Classical 90° Dynamic Light Scattering
Zeta Measurement Principle ELS with M3-PALS and Constant Current Zeta Mode ELS with M3-PALS and Constant Current Zeta Mode ELS with M3-PALS and Constant Current Zeta Mode
Molecular Weight and B22 Static Light Scattering (90° and 173°) Static Light Scattering (173°) Static Light Scattering (90°)
Optical Filter Wheel (Fluorescence/DDLS) Yes Yes No
Low Volume Disposable Sizing Cell with Extended Size Analysis Support Yes No Yes
MADLS® (High Resolution DLS) Yes No No
MADLS® - Particle Concentration/Titer Yes2 No No
21 CFR Part 11 compliant software Optional via Omnitrust Optional via Omnitrust Optional via Omnitrust
Size
Range2 0.3 nm to 10 μm 0.3 nm to 10 μm 0.3 nm to 10 μm
Minimum Volume 3 μL 12 μL 3 μL
Zeta potential
Size Range 3.8 nm to 100 μm 3.8 nm to 100 μm 3.8 nm to 100 μm
Minimum Volume3 20 μL 20 μL 20 μL

1  Red Label only
2  10 um by default. Option to extend for Zetasizer Lab and Zetasizer Ultra coming soon
3  Patented Diffusion Barrier method in capillary cell

Key applications

The Zetasizer Advance Range is suitable for a wide range of applications, including:

Colloidal Silica

Sizing of colloidal silica is a critical requirement. This is easily and reproducibly measured using the Zetasizer Lab Blue Label.

Titanium Dioxide

Titanium dioxide use is wide-ranging. When used in paints or inks, agglomerate or aggregate formation can diminish product performance. The Zetasizer Pro Blue Label, used alongside the MPT‑3 Autotitrator, characterizes the impact of salt concentration on the stability of TiO2 and identifies the most stable pH region.

Ceramics

The strength of ceramics is linked to particle size, and the Zetasizer Ultra Blue Label is ideally placed to measure this. Al2O3 samples are often made of differently-sized particles which can easily be identified using MADLS. In this 0.1% w/v sample, the two particle size populations would not be distinguishable with a single angle DLS measurement.

Proteins

For protein researchers, early access to characterization data can be a challenge, due to low sample volumes. This is easily overcome using the Zetasizer Lab Red Label with the capillary cell to confirm that samples meet quality requirements and that production and purification processes are optimized.

Carbon Dots (C-dots)

Photoluminescent C-dots are considered safer alternatives to quantum dots. Measuring fluorescent samples by DLS can be challenging due to additional photons emitted by the fluorophore. Available with NIBS on Zetasizer Pro Red Label, a filter removes this interference to provide accurate and reliable data.

Adeno-Associated Virus (AAV)

Monitoring viral concentration is important during development and production optimization. By using the Multi-Angle DLS (MADLS) based particle concentration measurement in the Zetasizer Ultra Red Label, both the size distribution and titer of the virus can be measured within a few minutes.

Industry applications

The Zetasizer Advance Range is used in many industries, including:

Academia

The Zetasizer Lab is an essential analytical tool for many academic laboratories worldwide, finding use in all applications where particle or molecular size and zeta potential analysis is required. The breadth of applications covered by Zetasizer systems, coupled with tens of thousands of scientific citations, have earned these instruments a central space in many scientific faculties.

Bioscience

Variations in molecule concentration, external temperature, level of agitation and time all impact the stability of biological molecules.  Instabilities mainly result in denaturation and aggregation of the molecule through which they can lose their biological function , elicit an immune response and consequently limit its therapeutic viability. Factors affecting therapeutic efficacy and immunogenicity therefore need to be monitored throughout the development pipeline especially at early stages to de-risk the biological drug molecule and limit late-stage failures. The Zetasizer range provides high quality, stability indicating data for biological drug molecules in a short time frame, enabling this measurement to be implemented throughout the development pipeline.

Food and drink

Zetasizer systems are used to analyze particle size and zeta potential to improve the appearance and taste of foods, drinks and flavorings, and optimize dispersion and emulsion stability to extend product shelf life and improve product performance.

Nanomaterials

Zetasizer measurements of nanoparticle size distribution, dispersion properties, stability and propensity to aggregate are crucial to the design of new nanomaterials. The very large surface area of such materials may result in novel physical and chemical properties, such as increased catalytic activity, improved solubility or unexpected optical or toxicological behavior.

Paints, inks and coatings

Paint, ink and coating formulations must be stable to keep them in an optimum state over time without change or aggregation. Particle size and zeta potential, measured by the Zetasizer instruments, play important roles in determining a product’s properties, such as dispersibility, color, strength, finish, durability and shelf life.

Pharmaceuticals

The correct particle size and zeta potential can help ensure the production of effective therapeutics, delivered safely. Zetasizer systems are used to characterize the stability and quality of dispersions, emulsions and creams, reducing formulation time and speeding new products to market.

High quality and reproducible results can be obtained. Especially, the experiment is easy to use and maintain. For ease of use, one can easily learn to perform after several minutes training. For after-sales care, it did not need to have any maintenance for several years. Thus, we believe that it is good value for money"

Mi Zhou — Sichuan University

Specification

Measurement principle Classical 90° Dynamic Light Scattering
Measurement angle 90°, 13° 1
Measurement range 0.3 nm - 15 μm 2
Minimum sample volume 3 μL
Concentration range
Minimum Sample Concentration:
Blue Label: 1 mg/mL 15 kDa Protein
Red Label: 0.3 mg/mL 15 kDa Protein
 
Maximum sample Concentration: 3
40% w/v

Accessories

Smart Manager

Unleash the potential of your data

Until now, instrument data has too often been stuck in manual records, spreadsheets or site-specific servers. By connecting your Zetasizer to our Smart Manager and continually analyzing instrument data in the cloud, you can unleash its full potential. This is just one of our digital solutions that are part of Malvern Panalytical's Smart Manager.

Smart Install

Get your new Zetasizer up and running faster when you choose to smart install. 

With comprehensive resources to help you quickly and safely set-up and verify the performance of your new instrument, there’s no need to wait for an engineer to do it for you. What’s more, smart install presents a new training opportunity as you receive full access to exclusive training material. 

How does it work?

When you follow the step-by-step video instructions, you could be up and running within 90 minutes of delivery of your new Zetasizer. 

You don't need any specific skills or knowledge to perform a smart installation. Simply follow the instructions provided. 

Everything needed to get started is provided with your new instrument – all you need is an internet connection to access the online training. 

Exclusive e-learning content

Resources to get you up and running quickly and with confidence include:  

  • detailed video guides walk you through installation and set-up;
  • 15-months  access to the Essentials e-learning course, which is provided at no extra cost;
  • a comprehensive user manual.

Find out more about smart install.

Manuals

Title Version Date Download
{{ row.title }} {{ row.softwareVersion }} {{ row.date }} Download

Sorry, no manuals are available for this product

Software

Title Version Date Download
{{ row.title }} {{ row.softwareVersion }} {{ row.date }} Download

Sorry, no software downloads are available for this product

Unleash the full potential of your Malvern Panalytical solution

[Technical support services cut corner engineer icon.jpg] Technical support services cut corner engineer icon.jpg

Unmatched uptime and performance


Malvern Panalytical instruments are built to last and good maintenance and care ensure continued peak performance for many years to come.

  • Service Agreements  build this into your schedule and budget, based on  preventive maintenance and remote support . Different levels include repair visits, response times and parts coverage as needed. OQ services, training and application consultancy can be added as well.

[PN13012_2520_CLV_Photography_MP_JN.jpg] PN13012_2520_CLV_Photography_MP_JN.jpg
Service Agreements
Find out more about our service agreement options tailored for you
Learn more >>

[Training and expertise cut corner presenter icon.jpg] Training and expertise cut corner presenter icon.jpg

Advanced analysis and actionable insights


  • Basic User Training : Master the art of optimal Zetasizer usage and determine whether your measurements, sample preparation, and data are accurate and reliable – all while uncovering invaluable maintenance tips and tricks.  Find your online or offline classroom training course .
  • Customized Application Training : A training journey personalized to your application needs , covering aspects from sample taking and method development to data and results interpretation. Our application scientists share in-depth theory and best practices to make sure you’re getting the most out of your Zetasizer measurements and instruments.
  • Analytical and Consultancy Services : Our expert services place specialists and scientists at your disposal for method development, sample preparation, and certification. From oxides to sulfides, from trace to major elements, from particle sizing to molecular interaction – gain unparalleled analytical expertise.  Find out more .
[Product support cut corner cog icon.jpg] Product support cut corner cog icon.jpg

Easy start and streamlined routine operations


  • Setting up for success: Our Zetasizer onboarding starts with our expert support engineers on-site, or if you’d like to set up the instrument yourself, our self-install will guide you. Either way, a comprehensive warranty and a starter training program are complimentary, so you can get straight to your important analyses.
  • Software and Manuals:  Easily find  manuals and our latest software versions  online to benefit from new features and to stay up to date.
  • Webinars and App Notes:  Access a  comprehensive catalog of resources , such as recorded webinars, white papers, and app notes to support your analytical journey. 
  • Parts and Consumables -   MyStoreOur online store  makes access to your parts, consumables, accessories, and software convenient and efficient. Check availability and pricing, self-service quotes and order on card or account, 24/7. 
  • Support Portal:  Our professional service team is ready to assist you – fast-track your service request on  Malvern Panalytical My Customer Support Portal  or view your system details and service history at a glance.
[Service team and contact cut corner agent icon.jpg] Service team and contact cut corner agent icon.jpg

Want to speak to a service expert or find the services that are just right for you?


Reach out to our experts and evaluate your services needs and business risks by answering a few questions around the usage of your Malvern Panalytical instrument.


Contact Service Team

*Please note that the exact details of our services and their availability are determined by a variety of customer-specific factors, such as product type, product configuration, or location.

Publications

Entry-level DLS with advanced functionality.

Entry-level DLS with advanced functionality.

Adaptive Correlation, M3-PALS and constant current zeta mode, with easy to use software and data quality feedback. All incorporated into a compact, user-friendly instrument.

Request a quote Request a demo