Turnkey solution for highly accurate elemental analysis of iron ore and DRI. Download now

Download now

The Metals edition of Zetium

The new element in metals

The Metals edition of the Zetium spectrometer is designed to deliver analytical excellence in the metals industry. It incorporates years of experience and the latest technology to meet the strictest process control targets, from raw materials to final and secondary products.

Looking for more information?

To request a quote, more information or download a brochure select an option below.

Overview

The Zetium Metals edition is pre-configured to deliver fast and reliable results from day 1 with the appropriate hardware and your choice of pre-calibrated application solutions, including:

  • NiFeCo - for the analysis of steels and alloys
  • Cu-Base - for the analysis of copper alloys
  • LAS - for the analysis of low-alloy steel

You can also choose to add WROXI, for the analysis of oxides in raw materials, or Stratos, for the analysis of coatings.

Applications

Like all Zetium spectrometers, the Metals edition delivers reliable analytical performance regardless of the application and excels in areas related to production control and R&D in metals, such as:   

  • Iron, nickel, and cobalt alloys 
  • Copper, aluminum, and titanium alloys 
  • Iron and steel
  • Precious metals 
  • Soldering alloys 
  • Scrap metals and unknown materials 
  • Slags
  • Raw materials
  • Single-layer or multi-layer coatings

SumXcore

SumXcore brings together the benefits of wavelength dispersive and energy dispersive XRF technology into one platform. This combination delivers unique advantages in the production of metals, including:

  • reductions in analysis time of up to 50 % for higher sample throughput or improved precision in a given time
  • identification of unexpected elements in production samples

For inclusion or homogeneity analysis, small spot mapping and elemental distribution analysis are possible with the ED core and unique translation mechanics.

Features

Design features for product consistency

  • High-capacity sample bed with a high-speed sample changer, ideal for medium to high sample throughput
  • Unrivalled analytical sensitivity at unprecedented speeds with superior detectors and counting electronics
  • Outlier detection and process control with Statistical Process Control software - ideal for traceability and accreditation
  • Continuous full-power operation for enhanced stability and repeatability
  • Ready for automated environments

Advanced software and unique application solutions

SuperQ

The latest version of our renowned SuperQ software features a new, streamlined user interface, advanced matrix correction algorithms, such as tertiary fluorescence, integration of ED deconvolution and integrated intelligence with the Virtual Analyst.

Type Standardization

A software module for SuperQ that allows users to add type standards to applications for automatic correction of results within user-defined limits

NiFeCo

A special set of samples developed to transfer calibrations based on more than 120 certified reference materials (CRMs) for accurate analysis of special steels, high-temperature alloys and super alloys

Cu-base

A carefully selected set of reference samples to set up calibrations for the analysis of copper-base metals, such as: 

  • Bronze (standard, aluminium, phosphor and leaded)
  • Brass (standard, alloyed and leaded)
LAS

A carefully selected set of reference samples to set up calibrations for the dedicated analysis of low alloy steel

Upgrade packages to meet every challenge

The modular design of the Zetium platform allows optimization of the Metals edition through the addition of upgrade packages that deliver tangible benefits:

  • SumXcore - for reduction in analysis times and identification of unexpected elements in production samples
  • Small Spot Mapping - ideal for the analysis of inclusions for process troubleshooting
  • Speed & throughput - for faster sample analysis
  • Robustness & uptime - for tough environments
  • Flexibility - to accomodate sample size variations
  • Performance enhancements - for superior sensitivity

Specification

Applications
Unique pre-calibration modules or calibration sets to enable accurate elemental analysis of a wide range of sample types, ideal for the metal manufacture, from process to quality control

One application of choice from:
NiFeCo
LAS
Cu-base
WROXI

Performance upgrades: Additional applications of choice
X-ray tubes
No-drift SST R-mAX 2.4 kW X-ray tube: Maximum uptime with minimum monitor correction

Performance upgrades: 3 or 4 kW X-ray tube for faster results and lower detection limits in the same measurement time
Options
Curved crystals for faster results
Up to 30% more intensity in the same measurement time
Shorter measurement time to achieve required limits

H-Per channels
Simultaneous measurement of up to two light elements (B, C, N, Na, Mg) to minimize total analysis time

SumXcore
Faster results in tandem with the WD functionality
Detect unexpected changes in composition

Small spot mapping
Unique compositional mapping with the ED core, for fast and accurate determination of compositional trends and heterogeneities

Accessories

User manuals

Software downloads

12 March 2026

Smart Instruments: Cloud Service Software update

Unleash the full potential of your Malvern Panalytical solution

[Technical support services cut corner engineer icon.jpg] Technical support services cut corner engineer icon.jpg

Unmatched uptime and performance


Malvern Panalytical instruments are built to last and good maintenance and care ensure continued peak performance for many years to come.

  • Service Agreements  build this into your schedule and budget, based on  preventive maintenance and remote support . Different levels include repair visits, response times and parts coverage as needed. OQ services, training and application consultancy can be added as well.
  • Smart Manager  goes even further:  Smart Manager  is a set of digital monitoring services combined with insight from experienced service professionals. Smart Manager is your trusted guardian for instrument health and utilization management, ensuring unrivaled accuracy, reliability, and efficiency in your analyses – on time, all the time.

[PN13012_2520_CLV_Photography_MP_JN.jpg] PN13012_2520_CLV_Photography_MP_JN.jpg
Service Agreements
Find out more about our service agreement options tailored for you
Learn more >>

[PN14321_Smart Manager Mastersizer Zetium graphic.jpg] PN14321_Smart Manager Mastersizer Zetium graphic.jpg
Smart Manager
Find out more about our instrument monitoring services
Learn more >>

[Training and expertise cut corner presenter icon.jpg] Training and expertise cut corner presenter icon.jpg

Advanced analysis and actionable insights


  • Basic User Training : Master the art of optimal Zetium usage and determine whether your measurements, sample preparation, and data are accurate and reliable – all while uncovering invaluable maintenance tips and tricks.  Find your online or offline classroom training course .
  • Customized Application Training : A training journey personalized to your application needs , covering aspects from sample taking and method development to data and results interpretation. Our application scientists share in-depth theory and best practices to make sure you’re getting the most out of your Zetium measurements and instruments.
  • Analytical and Consultancy Services : Our expert services place specialists and scientists at your disposal for method development, sample preparation, and certification. From oxides to sulfides, from trace to major elements, from particle sizing to molecular interaction – gain unparalleled analytical expertise.  Find out more .

[Scientist in laboratory with blue tint biologics pharmaceutical.png] Scientist in laboratory with blue tint biologics pharmaceutical.png
XRF testing services
Find out more about our custom XRF testing services
Learn more >>

[Product support cut corner cog icon.jpg] Product support cut corner cog icon.jpg

Easy start and streamlined routine operations


  • Setting up for success: Our Zetium onboarding starts with our expert support engineers on-site. A comprehensive warranty and a starter training program are complimentary, so you can get straight to your important analyses.
  • Software and Manuals:  Easily find  manuals and our latest software versions  online to benefit from new features and to stay up to date.
  • Webinars and App Notes:  Access a  comprehensive catalog of resources , such as recorded webinars, white papers, and app notes to support your analytical journey. 
  • Parts and Consumables -  MyStoreOur online store  makes access to your parts, consumables, accessories, and software convenient and efficient. Check availability and pricing, self-service quotes and order on card or account, 24/7. 
  • Support Portal:  Our professional service team is ready to assist you – fast-track your service request on  Malvern Panalytical My Customer Support Portal  or view your system details and service history at a glance.
[Service team and contact cut corner agent icon.jpg] Service team and contact cut corner agent icon.jpg

Want to speak to a service expert or find the services that are just right for you?


Reach out to our experts and evaluate your services needs and business risks by answering a few questions around the usage of your Malvern Panalytical instrument.


Contact Service Team

*Please note that the exact details of our services and their availability are determined by a variety of customer-specific factors, such as product type, product configuration, or location.

Publications

Overview

The Zetium Metals edition is pre-configured to deliver fast and reliable results from day 1 with the appropriate hardware and your choice of pre-calibrated application solutions, including:

  • NiFeCo - for the analysis of steels and alloys
  • Cu-Base - for the analysis of copper alloys
  • LAS - for the analysis of low-alloy steel

You can also choose to add WROXI, for the analysis of oxides in raw materials, or Stratos, for the analysis of coatings.

Applications

Like all Zetium spectrometers, the Metals edition delivers reliable analytical performance regardless of the application and excels in areas related to production control and R&D in metals, such as:   

  • Iron, nickel, and cobalt alloys 
  • Copper, aluminum, and titanium alloys 
  • Iron and steel
  • Precious metals 
  • Soldering alloys 
  • Scrap metals and unknown materials 
  • Slags
  • Raw materials
  • Single-layer or multi-layer coatings

SumXcore

SumXcore brings together the benefits of wavelength dispersive and energy dispersive XRF technology into one platform. This combination delivers unique advantages in the production of metals, including:

  • reductions in analysis time of up to 50 % for higher sample throughput or improved precision in a given time
  • identification of unexpected elements in production samples

For inclusion or homogeneity analysis, small spot mapping and elemental distribution analysis are possible with the ED core and unique translation mechanics.

Features

Design features for product consistency

  • High-capacity sample bed with a high-speed sample changer, ideal for medium to high sample throughput
  • Unrivalled analytical sensitivity at unprecedented speeds with superior detectors and counting electronics
  • Outlier detection and process control with Statistical Process Control software - ideal for traceability and accreditation
  • Continuous full-power operation for enhanced stability and repeatability
  • Ready for automated environments

Advanced software and unique application solutions

SuperQ

The latest version of our renowned SuperQ software features a new, streamlined user interface, advanced matrix correction algorithms, such as tertiary fluorescence, integration of ED deconvolution and integrated intelligence with the Virtual Analyst.

Type Standardization

A software module for SuperQ that allows users to add type standards to applications for automatic correction of results within user-defined limits

NiFeCo

A special set of samples developed to transfer calibrations based on more than 120 certified reference materials (CRMs) for accurate analysis of special steels, high-temperature alloys and super alloys

Cu-base

A carefully selected set of reference samples to set up calibrations for the analysis of copper-base metals, such as: 

  • Bronze (standard, aluminium, phosphor and leaded)
  • Brass (standard, alloyed and leaded)
LAS

A carefully selected set of reference samples to set up calibrations for the dedicated analysis of low alloy steel

Upgrade packages to meet every challenge

The modular design of the Zetium platform allows optimization of the Metals edition through the addition of upgrade packages that deliver tangible benefits:

  • SumXcore - for reduction in analysis times and identification of unexpected elements in production samples
  • Small Spot Mapping - ideal for the analysis of inclusions for process troubleshooting
  • Speed & throughput - for faster sample analysis
  • Robustness & uptime - for tough environments
  • Flexibility - to accomodate sample size variations
  • Performance enhancements - for superior sensitivity

Specification

Applications
Unique pre-calibration modules or calibration sets to enable accurate elemental analysis of a wide range of sample types, ideal for the metal manufacture, from process to quality control

One application of choice from:
NiFeCo
LAS
Cu-base
WROXI

Performance upgrades: Additional applications of choice
X-ray tubes
No-drift SST R-mAX 2.4 kW X-ray tube: Maximum uptime with minimum monitor correction

Performance upgrades: 3 or 4 kW X-ray tube for faster results and lower detection limits in the same measurement time
Options
Curved crystals for faster results
Up to 30% more intensity in the same measurement time
Shorter measurement time to achieve required limits

H-Per channels
Simultaneous measurement of up to two light elements (B, C, N, Na, Mg) to minimize total analysis time

SumXcore
Faster results in tandem with the WD functionality
Detect unexpected changes in composition

Small spot mapping
Unique compositional mapping with the ED core, for fast and accurate determination of compositional trends and heterogeneities

Accessories

User manuals

Software downloads

12 March 2026

Smart Instruments: Cloud Service Software update

Unleash the full potential of your Malvern Panalytical solution

[Technical support services cut corner engineer icon.jpg] Technical support services cut corner engineer icon.jpg

Unmatched uptime and performance


Malvern Panalytical instruments are built to last and good maintenance and care ensure continued peak performance for many years to come.

  • Service Agreements  build this into your schedule and budget, based on  preventive maintenance and remote support . Different levels include repair visits, response times and parts coverage as needed. OQ services, training and application consultancy can be added as well.
  • Smart Manager  goes even further:  Smart Manager  is a set of digital monitoring services combined with insight from experienced service professionals. Smart Manager is your trusted guardian for instrument health and utilization management, ensuring unrivaled accuracy, reliability, and efficiency in your analyses – on time, all the time.

[PN13012_2520_CLV_Photography_MP_JN.jpg] PN13012_2520_CLV_Photography_MP_JN.jpg
Service Agreements
Find out more about our service agreement options tailored for you
Learn more >>

[PN14321_Smart Manager Mastersizer Zetium graphic.jpg] PN14321_Smart Manager Mastersizer Zetium graphic.jpg
Smart Manager
Find out more about our instrument monitoring services
Learn more >>

[Training and expertise cut corner presenter icon.jpg] Training and expertise cut corner presenter icon.jpg

Advanced analysis and actionable insights


  • Basic User Training : Master the art of optimal Zetium usage and determine whether your measurements, sample preparation, and data are accurate and reliable – all while uncovering invaluable maintenance tips and tricks.  Find your online or offline classroom training course .
  • Customized Application Training : A training journey personalized to your application needs , covering aspects from sample taking and method development to data and results interpretation. Our application scientists share in-depth theory and best practices to make sure you’re getting the most out of your Zetium measurements and instruments.
  • Analytical and Consultancy Services : Our expert services place specialists and scientists at your disposal for method development, sample preparation, and certification. From oxides to sulfides, from trace to major elements, from particle sizing to molecular interaction – gain unparalleled analytical expertise.  Find out more .

[Scientist in laboratory with blue tint biologics pharmaceutical.png] Scientist in laboratory with blue tint biologics pharmaceutical.png
XRF testing services
Find out more about our custom XRF testing services
Learn more >>

[Product support cut corner cog icon.jpg] Product support cut corner cog icon.jpg

Easy start and streamlined routine operations


  • Setting up for success: Our Zetium onboarding starts with our expert support engineers on-site. A comprehensive warranty and a starter training program are complimentary, so you can get straight to your important analyses.
  • Software and Manuals:  Easily find  manuals and our latest software versions  online to benefit from new features and to stay up to date.
  • Webinars and App Notes:  Access a  comprehensive catalog of resources , such as recorded webinars, white papers, and app notes to support your analytical journey. 
  • Parts and Consumables -  MyStoreOur online store  makes access to your parts, consumables, accessories, and software convenient and efficient. Check availability and pricing, self-service quotes and order on card or account, 24/7. 
  • Support Portal:  Our professional service team is ready to assist you – fast-track your service request on  Malvern Panalytical My Customer Support Portal  or view your system details and service history at a glance.
[Service team and contact cut corner agent icon.jpg] Service team and contact cut corner agent icon.jpg

Want to speak to a service expert or find the services that are just right for you?


Reach out to our experts and evaluate your services needs and business risks by answering a few questions around the usage of your Malvern Panalytical instrument.


Contact Service Team

*Please note that the exact details of our services and their availability are determined by a variety of customer-specific factors, such as product type, product configuration, or location.

Next-level metal analysis.

Next-level metal analysis.

Pre-configured to deliver fast and reliable metal analysis results. Built on years of experience and the latest technology.

Request a quote Request a demo