The Petro edition of Zetium

The new element in petrochemicals

The Petro edition of the Zetium spectrometer is designed to deliver reliable and norm-compliant elemental analysis from crude oils to petrochemicals and fuels. 

Looking for more information?

To request a quote, more information or download a brochure select an option below.

Overview

The Petro edition of the Zetium spectrometer is pre-configured to deliver compliant results from day 1 with the appropriate hardware and your choice of compliance modules, which include factory pre-calibration according to ASTM and ISO international test methods. 

Inclusion of the innovative ED core, makes it the only XRF spectrometer capable of satisfying both WDXRF and EDXRF test methods using a single instrument. Inclusion of the innovative ED core not only delivers dual compliance but can be used to detect unexpected elements in production samples with simultaneous spectrum acquisition.

Applications

Like all Zetium spectrometers, the Petro edition delivers reliable analytical performance regardless of the application and excels in areas related to petrochemicals, such as:

  • Sulfur in petroleum products in accordance with relevant ISO and ASTM international test methods
  • Additives in unused lube oils according to ASTM 4927 and D6443 
  • Additives and wear metals in used lube oils
  • Single calibration for many oils, fuels and petrochemicals using the Oil-Trace package

Features

Design features for compliance

  • The 1 kW SST-R Rh tube delivers exceptional performance for the majority of applications (upgrades to 2.4, 3 and 4 kW available)
  • User-friendly software with integrated intelligence for novice and advanced users
  • Small sample load port volume minimizes helium consumption
  • Automatic sample recognition and vacuum-helium switching
  • Liquid cup construction tools for simple sample preparation

Upgrade packages to meet every challenge

The modular design of the Zetium platform allows optimization of the Petro edition through the addition of upgrade packages that deliver tangible benefits:

  • SumXcore - for reduction in analysis times and identification of unexpected elements in production samples
  • Small Spot Mapping - ideal for the analysis of inorganic inclusions (catalysts, additives, etc.) for process troubleshooting
  • Speed & throughput - for faster sample analysis
  • Robustness & uptime - for tough environments
  • Flexibility - to accomodate sample size variations
  • Performance enhancement - for superior sensitivity

Advanced software and unique application solutions

  • The latest version of our renowned SuperQ software features a new, streamlined user interface, advanced matrix correction algorithms, such as multi-scatter fluorescence, integration of ED deconvolution and integrated intelligence with the Virtual Analyst
  • Guaranteed compliance at start-up with factory pre-calibrated Compliance Modules: 
    • S in mineral oil (ASTM D2622) 
    • S in diesel (ASTM D2622) 
    • S in gasoline (ASTM D2622) 
    • Additives in lubrication oils (ASTM D6443)
  • Oil Trace eliminates mass/volume dependance and allows different types of petrochemicals to be measured against a single calibration, eliminating the cost of calibration samples and the time required to maintain multiple calibrations

Connected World

Unleash the potential of your data

Until now, instrument data has too often been stuck in manual records, spreadsheets or site-specific servers.

By connecting the Zetium to our Smart Manager and continually analyzing instrument data in the cloud, you can unleash its full potential.

This is just one of our digital solutions that are part of Malvern Panalytical's Connected World.

Specification

Applications
One application of choice from:
Guaranteed fuel compliance S in fuels and oils (ASTM D2622)
Guaranteed lube oil compliance (ASTM D6443)

Configuration upgrades
Oil-Trace: Eliminates mass/volume dependence and allows different types of petrochemicals to be measured against a single calibration, eliminating the cost of calibration samples and the time required to maintain multiple calibrations
X-ray tubes SST R 1 kW X-ray tube: Maximum uptime with minimum monitor correction

Configuration upgrades
3 or 4 kW X-ray tube: Faster results and lower detection limits in the same measurement time
Options
Configuration upgrades

Curved crystals for faster results
Up to 30% more intensity in the same measurement time
Shorter measurement time to achieve required limits

Duplex detector
Improved ‘catalyst killer’ elements detection, like nickel, iron and vanadium

SumXcore
Faster results in tandem with the WD functionality
Detect unexpected changes in composition

Small spot mapping
Unique compositional mapping with the ED core, for fast and accurate investigation of pipe scaling and other defects

Accessories

Manuals

Title Version Date Download
{{ row.pageTitle }} {{ row.softwareVersion }} {{ row.date }} Download

Sorry, no manuals are available for this product

Software

Title Version Date Download
{{ row.title }} {{ row.softwareVersion }} {{ row.date }} Download

Sorry, no software downloads are available for this product

Unleash the full potential of your Malvern Panalytical solution

[Technical support services cut corner engineer icon.jpg] Technical support services cut corner engineer icon.jpg

Unmatched uptime and performance


Malvern Panalytical instruments are built to last and good maintenance and care ensure continued peak performance for many years to come.

  • Service Agreements  build this into your schedule and budget, based on  preventive maintenance and remote support . Different levels include repair visits, response times and parts coverage as needed. OQ services, training and application consultancy can be added as well.
  • Smart Manager  goes even further:  Smart Manager  is a set of digital monitoring services combined with insight from experienced service professionals. Smart Manager is your trusted guardian for instrument health and utilization management, ensuring unrivaled accuracy, reliability, and efficiency in your analyses – on time, all the time.

[People in lab] shutterstock_1104131795.jpg
Service Agreements
Find out more about our service agreement options tailored for you
Learn more >>


[PN14321_Smart Manager Mastersizer Zetium graphic.jpg] PN14321_Smart Manager Mastersizer Zetium graphic.jpg
Smart Manager
Find out more about our instrument monitoring services
Learn more >>

[Training and expertise cut corner presenter icon.jpg] Training and expertise cut corner presenter icon.jpg

Advanced analysis and actionable insights


  • Basic User Training : Master the art of optimal Zetium usage and determine whether your measurements, sample preparation, and data are accurate and reliable – all while uncovering invaluable maintenance tips and tricks.  Find your online or offline classroom training course .
  • Customized Application Training : A training journey personalized to your application needs , covering aspects from sample taking and method development to data and results interpretation. Our application scientists share in-depth theory and best practices to make sure you’re getting the most out of your Zetium measurements and instruments.
  • Analytical and Consultancy Services : Our expert services place specialists and scientists at your disposal for method development, sample preparation, and certification. From oxides to sulfides, from trace to major elements, from particle sizing to molecular interaction – gain unparalleled analytical expertise.  Find out more .

[shutterstock_2189901805 cropped.jpg] shutterstock_2189901805 cropped.jpg
XRF testing services
Find out more about our custom XRF testing services
Learn more >>

[Product support cut corner cog icon.jpg] Product support cut corner cog icon.jpg

Easy start and streamlined routine operations


  • Setting up for success: Our Zetium onboarding starts with our expert support engineers on-site. A comprehensive warranty and a starter training program are complimentary, so you can get straight to your important analyses.
  • Software and Manuals:  Easily find  manuals and our latest software versions  online to benefit from new features and to stay up to date.
  • Webinars and App Notes:  Access a  comprehensive catalog of resources , such as recorded webinars, white papers, and app notes to support your analytical journey. 
  • Parts and Consumables -  MyStore :  Our online store  makes access to your parts, consumables, accessories, and software convenient and efficient. Check availability and pricing, self-service quotes and order on card or account, 24/7. 
  • Support Portal:  Our professional service team is ready to assist you – fast-track your service request on  Malvern Panalytical My Customer Support Portal  or view your system details and service history at a glance.
[Service team and contact cut corner agent icon.jpg] Service team and contact cut corner agent icon.jpg

Want to speak to a service expert or find the services that are just right for you?


Reach out to our experts and evaluate your services needs and business risks by answering a few questions around the usage of your Malvern Panalytical instrument.


Contact Service Team

*Please note that the exact details of our services and their availability are determined by a variety of customer-specific factors, such as product type, product configuration, or location.

Publications

The smart XRF spectrometer for the most demanding applications.

The smart XRF spectrometer for the most demanding applications.

Over 60 years' heritage and knowledge, combined with pre-configured editions for your industry and smart support services to unleash your data.

Contact sales Request a quote Request a demo