Comprehensive turnkey solutions for elemental analysis of all Rare Earth Elements (REEs). Download now

Download now

The Ultimate edition of Zetium

The new element in chemistry

The Ultimate edition of Zetium delivers unrivalled analytical performance regardless of the application. Dedicated application modules and solutions can be embedded in SuperQ software and come with templates and reference samples for effortless setup and simple calibration.

Looking for more information?

To request a quote, more information or download a brochure select an option below.

Overview

The Ultimate edition of the Zetium spectrometer represents the most advanced configuration in the Zetium family. The combination of WD and ED core and innovative technologies delivers analytical excellence in every situation, from R&D laboratories to high-throughput production facilities.

The Ultimate edition is pre-configured to deliver unrivaled sensitivity across the periodic table with thin-window, high-power tube technology, laterally curved crystals and unique detector technology, saving time and increasing sample throughput in busy laboratories.

Applications and software modules

Available application and software modules:

  • ADPOL
  • TOXEL
  • CEMOXI
  • WROXI
  • Oil-Trace
  • Pro-Trace
  • NiFeCo
  • Cu-base
  • LAS
  • Stratos 
  • Type Standardization

RoHS and petroleum standards

In addition Malvern Panalytical provides calibration standards for the analysis of RoHS elements and petroleum products.

The Ultimate edition also features Omnian, our market-leading standardless analysis module, for the qualitative and quantitative elemental analysis of unknown materials or materials where calibration samples are not readily available. 

In addition the inclusion of the SumXcore delivers significant advantages for conventional applications, such as reduced analytical times, identification of unexpected elements and spectrum archiving.

Adding small spot analysis and mapping option using the ED core allows practical, time-efficient data acquisition. The entire spectrum measured by the ED core at every spot significantly reduces measurement times and allows for standardless quantitative data capture.

Features

Sensitivity and throughput

  • High-capacity sample bed with a high-speed sample changer and continuous loading, ideal for high sample throughput
  • The 4 kW SST R-mAX50 Rh tube with CHI-BLUE coating delivers superior light-element excitation, without sacrificing robustness
  • A combination of flat, curved and multi-layer crystals for enhanced sensitivity across the periodic table provides calibration standards for the analysis of RoHS elements and petroleum products.

Upgrade packages to meet every challenge

Customized solutions to meet your needs:

  • Speed and throughput - for faster sample analysis
  • Robustness and uptime - for tough environments
  • Flexibility - to accomodate sample size variations
  • Performance enhancement - for superior sensitivity

Flexibility

The Omnian standardless analysis software and pre-calibration allows you to analyze unknown materials, or materials where no calibration standards are available.

Our entire range of application modules is compatible with the Ultimate edition. Some favorites include: 

  • Stratos - for the qualitative and quantitative analysis of layered materials, such as semiconductors, without the need for in-type calibration samples 
  • Pro-Trace delivers unrivalled trace element analysis of up to 44 elements in geological materials, without the need to determine major element concentrations first 
  • NiFeCo - a special set of samples developed to transfer calibrations based on more than 120 certified reference materials (CRMs) for accurate analysis of special steels, high-temperature alloys, and super alloys

Connected World

Unleash the potential of your data

Until now, instrument data has too often been stuck in manual records, spreadsheets or site-specific servers.

By connecting the Zetium to our Smart Manager and continually analyzing instrument data in the cloud, you can unleash its full potential.

This is just one of our digital solutions that are part of Malvern Panalytical's Connected World.

Specification

Applications Pre-calibration of Omnian package: Analysis of a wide variety of sample materials including rocks, ores, metals, plastics and oils

Performance upgrades
Applications of choice: Unique pre-calibration modules or calibration sets to enable accurate elemental analysis of a wide range of sample types, ideal for the metal manufacturer, from process to quality control
X-ray tubes No-drift SST R-mAX 4 kW X-ray tube, 50 micron window: Maximum uptime for consistent process control combined with ultra-light element enhancement and durability
Includes
Curved crystals
Up to 30% more intensity in the same measurement time
Shorter measurement time to achieve required limits

Duplex detector
Enhanced sensitivity and wider dynamic range for transition metals analysis

Hi-Per scint
Increased dynamic range for heavy elements (linear up to 3.5 Mcps)
High-precision analysis of Nb and Mo in steels
Options
Performance upgrades

SumXcore
Faster results in tandem with the WD functionality and possibility to detect unexpected changes in composition

Small spot mapping
Unique compositional mapping functionality attached to the ED screening, for fast and accurate determination of compositional trends and heterogeneities

Accessories

Manuals

Title Version Date Download
{{ row.title }} {{ row.softwareVersion }} {{ row.date }} Download

Sorry, no manuals are available for this product

Software

Title Version Date Download
{{ row.title }} {{ row.softwareVersion }} {{ row.date }} Download

Sorry, no software downloads are available for this product

Unleash the full potential of your Malvern Panalytical solution

[Technical support services cut corner engineer icon.jpg] Technical support services cut corner engineer icon.jpg

Unmatched uptime and performance


Malvern Panalytical instruments are built to last and good maintenance and care ensure continued peak performance for many years to come.

  • Service Agreements  build this into your schedule and budget, based on  preventive maintenance and remote support . Different levels include repair visits, response times and parts coverage as needed. OQ services, training and application consultancy can be added as well.
  • Smart Manager  goes even further:  Smart Manager  is a set of digital monitoring services combined with insight from experienced service professionals. Smart Manager is your trusted guardian for instrument health and utilization management, ensuring unrivaled accuracy, reliability, and efficiency in your analyses – on time, all the time.

[People in lab] shutterstock_1104131795.jpg
Service Agreements
Find out more about our service agreement options tailored for you
Learn more >>


[PN14321_Smart Manager Mastersizer Zetium graphic.jpg] PN14321_Smart Manager Mastersizer Zetium graphic.jpg
Smart Manager
Find out more about our instrument monitoring services
Learn more >>

[Training and expertise cut corner presenter icon.jpg] Training and expertise cut corner presenter icon.jpg

Advanced analysis and actionable insights


  • Basic User Training : Master the art of optimal Zetium usage and determine whether your measurements, sample preparation, and data are accurate and reliable – all while uncovering invaluable maintenance tips and tricks.  Find your online or offline classroom training course .
  • Customized Application Training : A training journey personalized to your application needs , covering aspects from sample taking and method development to data and results interpretation. Our application scientists share in-depth theory and best practices to make sure you’re getting the most out of your Zetium measurements and instruments.
  • Analytical and Consultancy Services : Our expert services place specialists and scientists at your disposal for method development, sample preparation, and certification. From oxides to sulfides, from trace to major elements, from particle sizing to molecular interaction – gain unparalleled analytical expertise.  Find out more .

[shutterstock_2189901805 cropped.jpg] shutterstock_2189901805 cropped.jpg
XRF testing services
Find out more about our custom XRF testing services
Learn more >>

[Product support cut corner cog icon.jpg] Product support cut corner cog icon.jpg

Easy start and streamlined routine operations


  • Setting up for success: Our Zetium onboarding starts with our expert support engineers on-site. A comprehensive warranty and a starter training program are complimentary, so you can get straight to your important analyses.
  • Software and Manuals:  Easily find  manuals and our latest software versions  online to benefit from new features and to stay up to date.
  • Webinars and App Notes:  Access a  comprehensive catalog of resources , such as recorded webinars, white papers, and app notes to support your analytical journey. 
  • Parts and Consumables -  MyStore :  Our online store  makes access to your parts, consumables, accessories, and software convenient and efficient. Check availability and pricing, self-service quotes and order on card or account, 24/7. 
  • Support Portal:  Our professional service team is ready to assist you – fast-track your service request on  Malvern Panalytical My Customer Support Portal  or view your system details and service history at a glance.
[Service team and contact cut corner agent icon.jpg] Service team and contact cut corner agent icon.jpg

Want to speak to a service expert or find the services that are just right for you?


Reach out to our experts and evaluate your services needs and business risks by answering a few questions around the usage of your Malvern Panalytical instrument.


Contact Service Team

*Please note that the exact details of our services and their availability are determined by a variety of customer-specific factors, such as product type, product configuration, or location.

Publications

The smart XRF spectrometer for the most demanding applications.

The smart XRF spectrometer for the most demanding applications.

Over 60 years' heritage and knowledge, combined with pre-configured editions for your industry and smart support services to unleash your data.

Contact sales Request a quote Request a demo