1. Руководства и программное обеспечение
  2. Варианты договора по сопровождению и поддержке
  3. Дополнительное оборудование
  4. Events and Training

Руководства и программное обеспечение


Варианты договора по сопровождению и поддержке

Protect your investment and ensure optimized performance at all times with Malvern Panalytical's service plans.

When you purchase a Malvern Panalytical product we understand that this is just the first stage of a working relationship that will last for the lifetime of the instrument. Depending on your needs, Malvern Panalytical will provide the support for your business.

Help Desk

Training

Software downloads

Malvern Panalytical's service options- choose the right plan for you:

PlatinumMedal

Malvern Panalytical Platinum Plan

For laboratories where maximizing instrument up-time is critical to its daily performance. Our highest level of response and the 'all inclusive' price plan takes care of those unexpected repair bills should the unfortunate occur.

GoldMedal

Malvern Panalytical Gold Plan

Enhance your laboratory productivity by maintaining instrument efficiency. Still receive that priority response, combined with specialist technical and software support, we'll keep your instrument performance on track to deliver.

BronzeMedal

Malvern Panalytical Bronze Visit

For laboratories looking to optimize instrument performance, regular preventative maintenance is essential.

Platinum PlanGold PlanBronze Visit
Annual PM/PV Test
yes
yes
no
Telephone / Email Support
yes
yes
no
Priority Response
yes
yes
no
Emergency Breakdown visits*
yes
yes
no
Parts Included
yes
no
no
E-Learning**
yes
yes
no
Technical & Software Support
yes
yes
yes
IQ/OQ (Pharma)***
yes
yes
yes

*including labour & travel costs** Platinum 2 places per contract term, Gold 1 place per contract term***available at an additional cost

Связаться со службой поддержки


Дополнительное оборудование

Дополнительное оборудование для облегчения работы или увеличения возможностей системы

Zetasizer Nano Z

Дополнительное оборудование

MPT-2

Image

Упрощение процесса исследования pH, проводимости и титрования добавок на вашем приборе Zetasizer Nano

Экономичный дополнительный компонент, предназначенный для автоматизации измерения размера и дзета-потенциала в зависимости от рН, проводимости или любой растворимой добавки.

Подробнее Запрос КП

Вискозиметр SV-10

Image

Быстрый, простой и точный процесс измерения вязкости.

SV-10 измеряет вязкость с точностью, необходимой для динамического рассеяния света, для преобразования скорости диффузии в размер и электрофоретической подвижности в дзета-потенциал в чрезвычайно простой и быстрой системе.

Подробнее Запрос КП

Опциональные кюветы

Одноразовая U-образная капиллярная кювета (DTS1070)

Image

Eliminate sample cross contamination between zeta potential measurements using a completely disposable cell.

The zeta potential of colloids and molecules is extremely sensitive to contamination from components of a previous sample used in a measurement cell. The use of a disposable cell completely eliminates this potential contamination issue.

The folded capillary cell provides the benefits of the accuracy of measurement of a capillary cell with the ease of use of a disposable cell.

Although, disposable, including the electrodes, for low conductivity samples each cell can be used for hundreds of measurements if required.

The cell can be used with the autotitrator, where multiple measurements are routinely done over a wide pH range.

Запрос КП

Universal 'dip' cell kit

Image

Reusable solvent resistant cell.

The dip cell is used for the measurement of zeta potential of samples in aqueous and non-aqueous dispersants, and is designed to be cleaned and reused. It is for batch measurements using standard polystyrene or glass cuvettes.
Запрос КП

High concentration zeta potential cell kit

Image

Экономия времени и трудозатрат при измерении дзета-потенциала слаборазбавленных или неразбавленных образцов.

The high concentration cell enables the measurement of the zeta potential of samples with little or no dilution in any Zetasizer Nano system that measures zeta potential.

The cell has a flow configuration so can be used for stop-flow size and zeta potential measurements using an MPT-2 autotitrator as well as batch measurements.

Запрос КП

Surface zeta potential accessory

Image

Расширение возможностей Zetasizer Nano для измерения дзета-потенциала поверхностей материалов.

Характеризация поверхности и границ раздела фаз очень важна во многих отраслях промышленности, в том числе при производстве товаров широкого потребления, продуктов тонкого органического синтеза, лекарственных препаратов и жизненно необходимых продуктов. В каждой из этих областей на свойства конечного продукта оказывает непосредственное влияние взаимодействие молекул и частиц с поверхностью и на границе раздела фаз.

The surface zeta potential accessory enables the measurement of the zeta potential of flat surfaces such as filter paper, silica, polymers and bone, using a standard Zetasizer Nano system.

Запрос КП

Кварцевая проточная кювета (ZEN0023)

Расширение возможностей Zetasizer при измерении размеров.

  • Измерение размера и интенсивности с помощью автотитратора MPT-2.
  • Подключение к системе ГПХ (GPC/SEC) для использования в качестве детектора динамического светорассеяния.
Запрос КП

12-мм стеклянная кювета (PCS1115)

Стеклянная кювета для использования с погружными электродами.

  • Для измерений размера и дзета-потенциала с помощью "погружных" электродов.
  • Совместима с водными и неводными растворителями и дисперсантами.
Запрос КП

Опции, устанавливаемые при производстве

Узкополосные фильтры

Их использование полезно в случае с флуоресцирующими образцами. Исключает сигнал от флуоресценции, что улучшает соотношение сигнал/фон.

Запрос КП

Способность выдерживать высокие температуры

Повышает способность выдерживать высокие температуры от 90 ºC до 120 ºC. Подходит для образцов в парафиновой среде, плавящихся при температуре свыше 90 ºC.

Запрос КП

Дегазатор для автотитратора MPT-2

Титранты, применяемые титратором MPT-2, нуждаются в регулярной дегазации, в идеале перед каждым титрованием.

Дегазация необходима для удаления пузырьков, которые могут повлиять на объем дозирования титранта. Это особенно важно при уровне рН, близком к 7, когда объём титранта должен быть небольшим.

Дегазатор является строго рекомендуемым дополнительным оборудованием, которое не требует вашего контроля и непрерывно выводит газ из титрантов, что повышает скорость титрования и точность достижения заданного рН. Это обеспечивает более равные промежутки между точками pH.

Запрос КП