Epsilon 1 for automotive catalysts recycling

Looking for an easy but accurate solution?

Looking for more information?

To request a quote, more information or download a brochure select an option below.

Overview

Want to get better accuracy and precision from your handheld XRF spectrometer, while keeping your workflow as simple as possible? Our Epsilon 1 ED-XRF spectrometer is here for you.

Epsilon 1 produces precise, accurate data – quickly, cost-effectively, and with minimal operator involvement or sample preparation. It’s set up for Pd, Pt, and Rh analysis directly from the factory, so you can get started straight away. And the spectrometer is designed for ultra-safe operations and reproducible sample positioning. Plus, with its compact, robust design, all you need is a regular main connection!

This easy operation makes Epsilon 1 the ideal choice for high-quality, on-site XRF analysis.

[icon calibrate.png] icon calibrate.png

Factory calibrated

[icon operator simplicity button.png] icon operator simplicity button.png

Operator friendly

[icon gamma-ray x-ray shielded.png] icon gamma-ray x-ray shielded.png

X-ray shielded

[icon trust shield with tick.png] icon trust shield with tick.png

High level of trust

Features

  • Easy communication: USB and network connections for standard computer peripherals support extended use, application development, and seated operator.

  • Spillage protection: a spillage protection foil is in place to shield the delicate heart of the system. In case of spillage, the foil can be replaced easily by the operator.

  • Self-contained system: A built-in computer running Windows 10 with a powerful CPU and 120 GB hard drive ensures flexibility to store and handle thousands of results. The high-resolution, 10.4” LCD touch screen is ideal for easy walk-up operation. To operate the analyzer, plug into a standard mains connection, and it is ready to power on. 

  • Sample calibration: for sample types that can't be calibrated, you can use a generic method to analyze elemental composition of a single sample with the Epsilon 1. Use our standardless Omnian software, combining twenty generic samples with the power of physics. Omnian can quantify elemental composition for a wide variety of sample types, including polymers and liquids. 

Robust and flexible quantification

Epsilon 1 will be pre-calibrated in the factory for analyzing of Pt, Pd and Rh in spent automotive catalytic convertors. Put loose powder in a sample cup and measure directly. 

The accuracy of the method is validated by measuring Certified Reference Materials. The results clearly demonstrate the capability of Epsilon 1 for the analysis of valuable precious metals Pt, Rh and Pd in catalytic converters. 

Sample name (repeats) Compounds Certified conc. Average conc. RMS Rel. RMS (%)
NIST 2556 (20x) Pt (ppm) 697.4 +/- 6.3 695.6 7.2 1.1
Rh (ppm) 51.2 +\- 0.5 53.9 2.0 3.7
Pd (ppm) 326 +/- 1.6 322.8 7.2 2.2
NIST 2557 (20x) Pt (ppm) 1131 +/- 1.9 1189.6 13.2 1.1
Rh (ppm) 135.1 +/- 1.9 141.6 2.2 1.6
Pd (ppm) 233.2 +/- 1.9 236.9 3.6 1.5
ERM-EB504a (5x) Pt (ppm) 1414 +/- 9.0 1424.8 5.1 0.4
Rh (ppm) 210 +/- 2.2 216.2 2.3 1.1
Pd (ppm) 1596 +/- 11 1675.1 18.3 1.1
FLX 133 (5x) Pt (ppm) 465 +/- 32 462.1 4.0 0.9
Rh (ppm) 242 +/- 4 237.6 4.0 1.7
Pd (ppm) 1075 +/- 33 1093.8 15.3 1.4

Guaranteed maximum safety

All Malvern Panalytical X-ray solutions are designed according to the strict regulations of regulatory bodies. The Epsilon 1 tabletop system shields its users against X-rays during analysis. 

You’ll have peace of mind in the lab thanks to a unique internal interlocked enclosure providing complete radiation protection, deserving its Vollshutz classification. 

No need to worry about safety as the system is fully enclosed and completely safe.

Very easy to use. Reproducible analysis. Very user-friendly.

Ivan Boninsegna — Aquafil S.p.a.

Specification

Sample loading Highly repeatable sample positioning
Sample size Typical 5 ml liquid
Safety Spillage protection against liquids
Dust and damage protection

Accessories

Smart Install

When correctly installed, your new Epsilon 1 will give you reliable analysis results. Installing an Epsilon 1 is straightforward: unpack the system, plug it in and follow the instructions, which we will guide you through. Finally, a simple radiation test completes the installation and confirms that your system is working safely. Yes, it is that easy to start using your Epsilon 1. And, more importantly, you can rest assured that your system is supplied with the necessary safety certification.

Smart install ensures you can get new instruments up and running even when unexpected circumstances or remote locations prevent an engineer from accessing your facility. For the Epsilon 1, we offer a guided  smart installation, enabling you to install the system yourself and maintain the integrity of the instrument and its safety certification.

The advantages of guided smart install:

  • Get up and running fast
  • Save on installation costs
  • Install the system when it suits you
  • Extended 15-month warranty period

Find out more about Smart Install.

User manuals

Software downloads

Please contact support for the latest software version.

Support

Self-support

Take a look at our basic instruction video series to learn more about Epsilon 1:

Services

Solutions to maximize the return on your investment

To assure that your instrument remains in top condition and performs on the highest level, Malvern Panalytical offers a wide range of services. Our expertise and support services assure an optimal functioning of your instrument.

Support

Service for a lifetime

  • Phone and remote support
  • Preventive maintenance and checkups
  • Flexible Customer Care Agreements
  • Performance certificates
  • Hardware and software upgrades
  • Local and global support

Expertise

Adding value to your processes 

  • Sample preparation development/optimization
  • Analytical methodologies 
  • Turnkey solutions for XRD 
  • Operations via IQ/OQ/PQ, quality assurance (GLP, ISO17025) or round robins/inter laboratory studies
  • Automation of lab processes
  • Consultancy services

Training and education

  • Training on-site or at our competence centers
  • Broad range of basic and advanced courses on products, applications and software

Analytical services and calibration materials

  • Expert (XRF) analyses services
  • Oxides and trace analysis
  • Customized calibration materials

Overview

Want to get better accuracy and precision from your handheld XRF spectrometer, while keeping your workflow as simple as possible? Our Epsilon 1 ED-XRF spectrometer is here for you.

Epsilon 1 produces precise, accurate data – quickly, cost-effectively, and with minimal operator involvement or sample preparation. It’s set up for Pd, Pt, and Rh analysis directly from the factory, so you can get started straight away. And the spectrometer is designed for ultra-safe operations and reproducible sample positioning. Plus, with its compact, robust design, all you need is a regular main connection!

This easy operation makes Epsilon 1 the ideal choice for high-quality, on-site XRF analysis.

[icon calibrate.png] icon calibrate.png

Factory calibrated

[icon operator simplicity button.png] icon operator simplicity button.png

Operator friendly

[icon gamma-ray x-ray shielded.png] icon gamma-ray x-ray shielded.png

X-ray shielded

[icon trust shield with tick.png] icon trust shield with tick.png

High level of trust

Features

  • Easy communication: USB and network connections for standard computer peripherals support extended use, application development, and seated operator.

  • Spillage protection: a spillage protection foil is in place to shield the delicate heart of the system. In case of spillage, the foil can be replaced easily by the operator.

  • Self-contained system: A built-in computer running Windows 10 with a powerful CPU and 120 GB hard drive ensures flexibility to store and handle thousands of results. The high-resolution, 10.4” LCD touch screen is ideal for easy walk-up operation. To operate the analyzer, plug into a standard mains connection, and it is ready to power on. 

  • Sample calibration: for sample types that can't be calibrated, you can use a generic method to analyze elemental composition of a single sample with the Epsilon 1. Use our standardless Omnian software, combining twenty generic samples with the power of physics. Omnian can quantify elemental composition for a wide variety of sample types, including polymers and liquids. 

Robust and flexible quantification

Epsilon 1 will be pre-calibrated in the factory for analyzing of Pt, Pd and Rh in spent automotive catalytic convertors. Put loose powder in a sample cup and measure directly. 

The accuracy of the method is validated by measuring Certified Reference Materials. The results clearly demonstrate the capability of Epsilon 1 for the analysis of valuable precious metals Pt, Rh and Pd in catalytic converters. 

Sample name (repeats) Compounds Certified conc. Average conc. RMS Rel. RMS (%)
NIST 2556 (20x) Pt (ppm) 697.4 +/- 6.3 695.6 7.2 1.1
Rh (ppm) 51.2 +\- 0.5 53.9 2.0 3.7
Pd (ppm) 326 +/- 1.6 322.8 7.2 2.2
NIST 2557 (20x) Pt (ppm) 1131 +/- 1.9 1189.6 13.2 1.1
Rh (ppm) 135.1 +/- 1.9 141.6 2.2 1.6
Pd (ppm) 233.2 +/- 1.9 236.9 3.6 1.5
ERM-EB504a (5x) Pt (ppm) 1414 +/- 9.0 1424.8 5.1 0.4
Rh (ppm) 210 +/- 2.2 216.2 2.3 1.1
Pd (ppm) 1596 +/- 11 1675.1 18.3 1.1
FLX 133 (5x) Pt (ppm) 465 +/- 32 462.1 4.0 0.9
Rh (ppm) 242 +/- 4 237.6 4.0 1.7
Pd (ppm) 1075 +/- 33 1093.8 15.3 1.4

Guaranteed maximum safety

All Malvern Panalytical X-ray solutions are designed according to the strict regulations of regulatory bodies. The Epsilon 1 tabletop system shields its users against X-rays during analysis. 

You’ll have peace of mind in the lab thanks to a unique internal interlocked enclosure providing complete radiation protection, deserving its Vollshutz classification. 

No need to worry about safety as the system is fully enclosed and completely safe.

Very easy to use. Reproducible analysis. Very user-friendly.

Ivan Boninsegna — Aquafil S.p.a.

Specification

Sample loading Highly repeatable sample positioning
Sample size Typical 5 ml liquid
Safety Spillage protection against liquids
Dust and damage protection

Accessories

Smart Install

When correctly installed, your new Epsilon 1 will give you reliable analysis results. Installing an Epsilon 1 is straightforward: unpack the system, plug it in and follow the instructions, which we will guide you through. Finally, a simple radiation test completes the installation and confirms that your system is working safely. Yes, it is that easy to start using your Epsilon 1. And, more importantly, you can rest assured that your system is supplied with the necessary safety certification.

Smart install ensures you can get new instruments up and running even when unexpected circumstances or remote locations prevent an engineer from accessing your facility. For the Epsilon 1, we offer a guided  smart installation, enabling you to install the system yourself and maintain the integrity of the instrument and its safety certification.

The advantages of guided smart install:

  • Get up and running fast
  • Save on installation costs
  • Install the system when it suits you
  • Extended 15-month warranty period

Find out more about Smart Install.

User manuals

Software downloads

Please contact support for the latest software version.

Support

Self-support

Take a look at our basic instruction video series to learn more about Epsilon 1:

Services

Solutions to maximize the return on your investment

To assure that your instrument remains in top condition and performs on the highest level, Malvern Panalytical offers a wide range of services. Our expertise and support services assure an optimal functioning of your instrument.

Support

Service for a lifetime

  • Phone and remote support
  • Preventive maintenance and checkups
  • Flexible Customer Care Agreements
  • Performance certificates
  • Hardware and software upgrades
  • Local and global support

Expertise

Adding value to your processes 

  • Sample preparation development/optimization
  • Analytical methodologies 
  • Turnkey solutions for XRD 
  • Operations via IQ/OQ/PQ, quality assurance (GLP, ISO17025) or round robins/inter laboratory studies
  • Automation of lab processes
  • Consultancy services

Training and education

  • Training on-site or at our competence centers
  • Broad range of basic and advanced courses on products, applications and software

Analytical services and calibration materials

  • Expert (XRF) analyses services
  • Oxides and trace analysis
  • Customized calibration materials
Small, powerful, portable XRF.

Small, powerful, portable XRF.

Fully integrated EDXRF analysis. Pre-calibrated for your industry. Ready for fast quantification in the lab - or to take on the road with you.

Contact sales Request a quote Request a demo