OMNISEC is a powerful tool for taking control of the performance, quality and value of your product, whether that’s a synthetic polymer in industry, a natural polymer or polysaccharide used in food or pharmaceutical products, or a protein or antibody used in biopharmaceuticals.

As a research tool, it accelerates research into these molecules by providing absolute information for a wide range of applications making it an ideal tool for universities. It reduces service expense and downtime and increases productivity with easy-to-use intuitive software.

With OMNISEC you can…Of…
Control strength, toughness, durability, brittleness, processability and branchingPolystyrene, nylon, PET, PVC, polyester, nitrocellulose, resins, epoxys, polyurethanes, PVA
Measure degradation and drug delivery ratesPLA, PLGA, PEG, polycaprolocatone
Grade natural polymers and polysaccharidesAlginates, xanthans, Gum Arabic, starch derivatives (e.g. maltodextrin), cellulose derivatives (e.g. HEC), carageenan, gelatin, guar gum, chitosan, hyaluronic acid
Control formulation viscosityAlkyds, acrylics, polyurethanes, polyesters, resins, epoxys, PVA,
Control food mouth-feel and gellingPectins, alginates, xanthans, Gum Arabic, guar gum, starch derivatives (e.g. maltodextrin), carageenans
Assess and predict activity by measuring molecular weightProteins, antibodies, mAbs
Predict and understand immunogenicity and efficacyAggregates of proteins, biopharmaceuticals, biologics and mAbs
Control half-life, cell permeability and understand crystallization of protein conjugatesPEGylated proteins, membrane proteins, antibody-drug-conjugates

In size-exclusion chromatography, molecules are separated according to their hydrodynamic radius as they enter and exit the pores of a porous gel packing matrix in the column. Like other HPLC-based techniques, this involves the use of a pump, column and at least one detector to measure the sample as it elutes. An OMNISEC GPC/SEC system includes the following components:

Degasser

  • Rapid mobile-phase exchange thanks to low volume degasser

Pump

  • Rapid mobile-phase exchange thanks to self-priming pump
  • Reduced service requirement thanks to novel continuous back seal flushing mechanism

Autosampler

  • Protect samples from aggregation with autosampler temperature control
  • Use your preferred sample format; vials or 96-well microtiter plates
  • Reduce sample use with zero-waste mode

Column Oven

  • Temperature control of up to 6 analytical columns

Refractive Index

  • Measure the concentration of any solute with excellent sensitivity

UV/Vis PDA

  • Measure absorbance at any wavelength from 190-900 nm
  • Assess changes in absorbance spectra
  • Characterize copolymers

Light Scattering

  • Measure absolute molecular weight in a wider range of applications
  • Measure as little as 100 ng of material
  • Measure molecular weights down to 200 Da

Viscometer

  • Better intrinsic viscosity measurements thanks to automated balancing
  • Reduced service cost and time thanks to user-exchangeable capillaries

OMNISEC RESOLVE

Скорость потока:
0.005 - 10 mL/min
Flow rate accuracy:
±1%
Pressure range:
0 - 5000 PSI (34.5 MPa)
Пульсации:
0.15% @ 1 mL/min in water
Габариты (Ш, Г, В):
420, 640, 890 mm
Вес:
62 kg
Программное обеспечение:
OMNISEC software v10 (or later)
Частота регистрации данных:
100 Hz
Patents:
US 14/599,033 "Continuous back seal wash"

AUTOSAMPLER

Вместимость:
Up to 192
Sample container types:
HPLC vials or 96-well microtiter plates
Вводимый объём пробы:
1 - 300 µL
Injection volume accuracy:
>99.5%
Injection volume precision:

<0.3% RSD in full loop mode

<0.5% RSD in partial loop mode

<1% RSD in µL pickup mode

Injection overhead volume:
0 µL in µL pickup mode
Syringe volume:
250 µL standard
Диапазон регулирования температур:
4 - 60 °C

COLUMN OVEN

Column capacity:
6 x analytical (1 x Tricorn 10/300 GL)
Диапазон регулирования температур:
20 - 65 °C

OMNISEC REVEAL

Габариты (Ш, Г, В):
420, 640, 600 mm
Вес:
40 kg
Detector temperature range:
20 - 65 °C
Программное обеспечение:
OMNISEC software v10 (or later)
Частота регистрации данных:
100 Hz
Patents:

US20140060162A1 & EP2619543Ba "Modular capillary bridge viscometer"

US20140144214A1 & EP2619544A1 "Automatically balanced capillary bridge viscometer"

Detector 1

Детектор:
Light scattering
Принцип измерения:
RALS 90° angle, LALS 7° angle
Источник света:
50 mW, 640 nm laser
Объём кюветы:
18 µL
Динамический диапазон:
2500 mV
Baseline noise:
<0.1 mV
Baseline drift:
<0.2 mV/hr

Detector 2

Детектор:
Differential refractive index
Принцип измерения:
Deflection
Объём кюветы:
12 µL
Динамический диапазон:
±2.5 x 10-4 RIU
Baseline noise:
<10-7 RIU
Baseline drift:
<3 x 10-7 RIU/hr

Detector 3

Детектор:
Viscometer
Принцип измерения:
4-capillary Wheatstone bridge with self-balancing mechanism and user-exchangeable capillaries
Датчики давления:
Firmware-based transducer overpressure protection
Detector volume:
17 µL/capillary
Differential pressure baseline noise:
0.3 Pa
Inlet pressure dynamic range:
100 kPa
Inlet pressure baseline noise:
0.01 kPa
Baseline drift:
<0.2 kPa/hr

Detector 4

Детектор:
Diode-array-based UV/Vis spectrometer
Длина волны регистрации:
190 - 900 nm
Number of wavelengths:
1024
Wavelength accuracy:
<1 nm
Wavelength resolution:
0.6 nm
Объём кюветы:
7.5 µL
Path length:
10 mm
Baseline noise:
2 x 10-5 AU
Baseline drift:
5 x 10-4 AU/hr

Measurement type 1

Анализируемые свойства:
Absolute molecular weight
Диапазон измерения:
200 - >107 g/mol
Minimum quantifiable mass:
100 ng of 100kDa molecular weight polystyrene in THF
Принцип измерения:
Light scattering (LALS or RALS)

Measurement type 2

Анализируемые свойства:
Intrinsic viscosity
Minimum quantifiable mass:
1 µg of 100kDa molecular weight polystyrene in THF
Принцип измерения:
4-capillary Wheatstone bridge

Measurement type 3

Анализируемые свойства:
Concentration
Minimum quantifiable mass:
100 ng of 100kDa molecular weight polystyrene in THF
Принцип измерения:
Differential refractive index detection

Operating environment

Температура:
15 - 30 °C

Software

Требования к ПК/ОС:
Windows 7 Professional 64 bit, 4th Gen Intel(R) Core I7 Processor (Quad Core HT, 3.4 GHz Turbo, w/ HD Graphics), 8 GB 1600 MHz DDR3 memory, 500 GB 3.5 inch SATA (7200 RPM) HDD, Full-HD monitor

OMNISEC

OMNISEC RESOLVE

Combined pump, degasser, autosampler and column oven, for high quality GPC/SEC and accurate molecular weight measurement.

Image

OMNISEC RESOLVE combines with OMNISEC REVEAL to form a complete OMNISEC GPC/SEC solution for the measurement of absolute molecular weight, intrinsic viscosity and other parameters. It combines an integrated pump, degasser, autosampler and column oven in a single advanced separations unit.

Подробнее

OMNISEC REVEAL

The ultimate in integrated advanced detection for GPC/SEC

Image

Molecular weight, intrinsic viscosity and numerous other parameters can be measured with OMNISEC REVEAL, the world’s most advanced integrated GPC/SEC multi-detector available. It can be added to any existing conventional GPC/SEC system or used in conjunction with OMNISEC RESOLVE to form a complete GPC/SEC solution, to offer comprehensive molecular characterization of synthetic and natural polymers, as well as proteins.

Подробнее

OMNISEC software

Powerful, agile, easy to use GPC/SEC software for OMNISEC instrument control, data acquisition, analysis and reporting

Image

OMNISEC software is an integrated solution for the advanced analysis of proteins and polymers by GPC/SEC, and is specifically designed for control of OMNISEC RESOLVE and OMNISEC REVEAL. Simplified workflows improve productivity and help you to maximize the information and efficiency of your experiments. Simply load your samples and the software controls all the sequencing, enabling truly automatic unattended operation.

Подробнее

Viscotek Columns

GPC/SEC columns for all aqueous and organic applications

Image

A wide range of columns for analytical GPC/SEC of synthetic and natural polymers and proteins

Подробнее

Viscotek Standards

A range of molecular weight standards for different applications of GPC/SEC

Image

Malvern offers a wide range of molecular weight standards for GPC/SEC for conventional and universal calibration as well as light scattering.

Подробнее

Protect your investment and ensure optimized performance at all times with Malvern Panalytical's service plans.

When you purchase a Malvern Panalytical product we understand that this is just the first stage of a working relationship that will last for the lifetime of the instrument. Depending on your needs, Malvern Panalytical will provide the support for your business.

Help Desk

Training

Software downloads

Malvern Panalytical's service options- choose the right plan for you:

Malvern Panalytical Platinum Plan

For laboratories where maximizing instrument up-time is critical to its daily performance. Our highest level of response and the 'all inclusive' price plan takes care of those unexpected repair bills should the unfortunate occur.

Malvern Panalytical Gold Plan

Enhance your laboratory productivity by maintaining instrument efficiency. Still receive that priority response, combined with specialist technical and software support, we'll keep your instrument performance on track to deliver.

Malvern Panalytical Bronze Visit

For laboratories looking to optimize instrument performance, regular preventative maintenance is essential.

Platinum PlanGold PlanBronze Visit
Annual PM/PV Test
yes
yes
no
Telephone / Email Support
yes
yes
no
Priority Response
yes
yes
no
Emergency Breakdown visits*
yes
yes
no
Parts Included
yes
no
no
Technical & Software Support
yes
yes
yes
IQ/OQ (Pharma)***
yes
yes
yes

*including labour & travel costs***available at an additional cost