The Cement edition of Zetium

The new element in cement

The Cement edition of Zetium provides cement manufacturers with the perfect tool for rapid and robust analysis during all stages in the cement production process. The Zetium XRF spectrometer does not only analyze the composition of the raw material up to the final cement. Accuracy of the cement analysis is guaranteed by following the ASTM C114 norm as well as the ISO 29581-2 norm.

Looking for more information?

To request a quote, more information or download a brochure select an option below.

Features

Elemental analysis

Zetium is capable of analyzing all major and minor elements and compounds in the entire cement production, such as raw materials, raw meal, kiln feed, clinker and cement.

Typical errors, including sample handling and sample preparation, are less than 1% relative.

Calibration maintenance

Calibration maintenance is a routine operation based on a limited number of instrument control samples and drift monitors. 

These samples do not require maintenance and can be used over the whole lifetime of the instrument.

The SuperQ software of the Cement edition of Zetium allows setting up automatic routine maintenance at chosen time intervals without human interference.

Fast response

The Zetium’s short measurement times for accurate analysis guarantee fast response to production control systems while requirements for expensive and time or labor-intensive wet chemistry are virtually eliminated.

When configured with the ED core, the time for the elemental analysis can be reduced even further. 

The ED core also stores measured spectra to help improve traceability of production quality. 

Automation

The Cement edition of Zetium can easily be integrated into automated sample preparation and analysis systems. The spectrometer can receive samples from three sides, allowing for flexible system setup. In most cases, the instrument can even be fitted into existing systems, reducing the need for expensive laboratory re-designs. 

The integrated robotic sample handler picks up samples from transfer points and loads them into the spectrometer while the software interface transfers sample information to the Zetium spectrometer and transmits analysis results to the LIMS and/or plant control system. The system’s intelligence allows for additional (manually entered) samples to be analyzed in between the automatically fed production samples without any operator attendance.

Malvern Panalytical can provide automated systems as turn-key solutions in cooperation with world-renowned suppliers of sample preparation equipment.

Solid return on investment

The Cement edition of Zetium eliminates the need for multiple instruments (for elemental and for structural analysis), ensuring an optimal return on investment with minimal cost of operation.

The built-in flexibility allows for additional analytical tasks (for example, analysis of alternative fuels) without the need for additional analytical equipment.

The easy-to-use software enables even less experienced staff to operate the instrument without risk of making mistakes.

Connected World

Unleash the potential of your data

Until now, instrument data has too often been stuck in manual records, spreadsheets or site-specific servers.

By connecting the Zetium to our Smart Manager and continually analyzing instrument data in the cloud, you can unleash its full potential.

This is just one of our digital solutions that are part of Malvern Panalytical's Connected World.

Specification

Sample loading Fast sample changer and turret-style loading
Power 3 kW
X-ray tubes 2.4 kW SST-R Rh drift-free, super-sharp SST R X-ray tubes feature new technology for improved robustness
Optional upgrade to 3 or 4 kW SST-R Rh
Certification WROXI or sample certification: Certification of up to 25 of your own samples by our ISO 17025-certified laboratory, for use as in-house calibration or monitor samples
Cleaning routines Dust collection and removal kit included: removes dust from the sample prior to loading
Sensor type Sample breakage sensor: senses if the sample breaks during loading and prevents introduction into the measurement chamber
Protecting tube CHI-BLUE tube window coating protects tube window from contamination without affecting the X-ray output

Accessories

Manuals

Title Version Date Download
{{ row.title }} {{ row.softwareVersion }} {{ row.date }} Download

Sorry, no manuals are available for this product

Software

Title Version Date Download
{{ row.title }} {{ row.softwareVersion }} {{ row.date }} Download

Sorry, no software downloads are available for this product

Unleash the full potential of your Malvern Panalytical solution

[Technical support services cut corner engineer icon.jpg] Technical support services cut corner engineer icon.jpg

Unmatched uptime and performance


Malvern Panalytical instruments are built to last and good maintenance and care ensure continued peak performance for many years to come.

  • Service Agreements  build this into your schedule and budget, based on  preventive maintenance and remote support . Different levels include repair visits, response times and parts coverage as needed. OQ services, training and application consultancy can be added as well.
  • Smart Manager  goes even further:  Smart Manager  is a set of digital monitoring services combined with insight from experienced service professionals. Smart Manager is your trusted guardian for instrument health and utilization management, ensuring unrivaled accuracy, reliability, and efficiency in your analyses – on time, all the time.

[People in lab] shutterstock_1104131795.jpg
Service Agreements
Find out more about our service agreement options tailored for you
Learn more >>


[PN14321_Smart Manager Mastersizer Zetium graphic.jpg] PN14321_Smart Manager Mastersizer Zetium graphic.jpg
Smart Manager
Find out more about our instrument monitoring services
Learn more >>

[Training and expertise cut corner presenter icon.jpg] Training and expertise cut corner presenter icon.jpg

Advanced analysis and actionable insights


  • Basic User Training : Master the art of optimal Zetium usage and determine whether your measurements, sample preparation, and data are accurate and reliable – all while uncovering invaluable maintenance tips and tricks.  Find your online or offline classroom training course .
  • Customized Application Training : A training journey personalized to your application needs , covering aspects from sample taking and method development to data and results interpretation. Our application scientists share in-depth theory and best practices to make sure you’re getting the most out of your Zetium measurements and instruments.
  • Analytical and Consultancy Services : Our expert services place specialists and scientists at your disposal for method development, sample preparation, and certification. From oxides to sulfides, from trace to major elements, from particle sizing to molecular interaction – gain unparalleled analytical expertise.  Find out more .

[shutterstock_2189901805 cropped.jpg] shutterstock_2189901805 cropped.jpg
XRF testing services
Find out more about our custom XRF testing services
Learn more >>

[Product support cut corner cog icon.jpg] Product support cut corner cog icon.jpg

Easy start and streamlined routine operations


  • Setting up for success: Our Zetium onboarding starts with our expert support engineers on-site. A comprehensive warranty and a starter training program are complimentary, so you can get straight to your important analyses.
  • Software and Manuals:  Easily find  manuals and our latest software versions  online to benefit from new features and to stay up to date.
  • Webinars and App Notes:  Access a  comprehensive catalog of resources , such as recorded webinars, white papers, and app notes to support your analytical journey. 
  • Parts and Consumables -  MyStore :  Our online store  makes access to your parts, consumables, accessories, and software convenient and efficient. Check availability and pricing, self-service quotes and order on card or account, 24/7. 
  • Support Portal:  Our professional service team is ready to assist you – fast-track your service request on  Malvern Panalytical My Customer Support Portal  or view your system details and service history at a glance.
[Service team and contact cut corner agent icon.jpg] Service team and contact cut corner agent icon.jpg

Want to speak to a service expert or find the services that are just right for you?


Reach out to our experts and evaluate your services needs and business risks by answering a few questions around the usage of your Malvern Panalytical instrument.


Contact Service Team

*Please note that the exact details of our services and their availability are determined by a variety of customer-specific factors, such as product type, product configuration, or location.

Publications

Precision you can build on.

Precision you can build on.

From raw mix to final product, Zetium Cement Edition delivers the accuracy, speed, and consistency your cement lab needs - day in, day out.

Contact sales Request a quote Request a demo