X'Pert³ is now a Smart Instrument!. Find out more

Find out more

X'Pert³ MRD XL

Versatile research, development & quality control XRD system

  • Full wafer mapping up to 200 mm
  • Versatile X-ray scattering platform
  • Improved performance and reliability

Select a model:

Looking for more information?

To request a quote, more information or download a brochure select an option below.

Overview

The long and successful history of Malvern Panalytical's Materials Research Diffractometers (MRD) continues with the generation of X’Pert³ MRD XL. 

The improved performance and reliability of the new platform have added more analytical capability and power for X-ray scattering studies in:

  • advanced materials science
  • scientific and industrial thin film technology
  • metrological characterization in semiconductor process development

The X’Pert³ MRD XL handles a wide range of applications with full wafer mapping up to 200 mm.

Futureproof system flexibility

The X'Pert³ MRD systems offer advanced and innovative X-ray diffraction solutions from research to process development and process control. 

These technologies make all systems field-upgradable to all existing options and new developments in hardware and software to come.

Extended MRD (XL)

The X'Pert³ Extended MRD (XL) brings increased versatility to the range of X'Pert³ MRD systems. An extra PreFIX mounting platform allows mounting of an X-ray mirror and a high-resolution monochromator in-line, significantly increasing the intensity of the incident beam.

You can benefit from increased application versatility without compromise on data quality, high-resolution X-ray diffraction with high intensities, shorter measurement times for measurements such as reciprocal space mapping and rebuild from standard to extended configuration in minutes thanks to the PreFIX concept. With the 2nd generation PreFIX, reconfiguring is easy and optics positioning is more accurate than ever.

MRD (XL) In-plane

With the X'Pert³ MRD (XL) system for in-plane diffraction, it becomes possible to measure diffraction from lattice planes that are perpendicular to the sample surface.

Standard and in-plane geometries on one system and a wide range of diffraction experiments on polycrystalline and highly perfect thin films, are just two of many benefits. 

Download the brochure: Semiconductor wafers - Crystalline quality

Key applications

The Malvern Panalytical X’Pert³ MRD and MRD XL are all-in-one X-ray solution systems that can be used in many industry applications, including:

Semiconductors and single crystal wafers

Whether for growth studies or device design, the measurement of layer quality, thickness, strain and alloy composition using high-resolution XRD has been at the heart of research and development in electronic and optoelectronic multilayer semiconductor devices. With a choice of X-ray mirrors, monochromators and detectors, the X’Pert3 MRD and MRD XL offer high-resolution configurations to suit different materials systems ranging from lattice-matched semiconductors, through relaxed buffer layers on to novel exotic layers on non-standard substrates

Polycrystalline solids and thin films

Polycrystalline layers and coatings are an important component of many thin films and multilayer devices. The evolution of polycrystalline layer morphology during deposition is a key study area in functional materials research and development. X’Pert3 MRD and X’Pert3 MRD XL can be fully equipped with a range of slits, parallel beam X-ray mirror, polycapillary lens, crossed slits and monocapillaries to give the full choice of incident beam optics for reflectometry, stress, texture and phase ID.

Ultra-thin films, nanomaterials and amorphous layers

Functional devices may contain disordered, amorphous or nanocomposite thin films. The flexibility of the X’Pert3 MRD and MRD XL systems allows for the incorporation of multiple analytical methods. A range of high-resolution optics, slits and parallel plate collimators are available to give the optimum performance for grazing incidence methods, in-plane diffraction and reflectometry.

Measurement under non-ambient conditions

Studying the behavior of materials under a variety of conditions is an essential part of materials research and process development. The X’Pert3 MRD and MRD XL are designed for the easy incorporation of the DHS1100 non-ambient sample stage from Anton Paar, enabling automated measurements under a range of temperatures and inert atmosphere

Instrument gives excellent accuracy and is of good quality.Good intensity and rapid performance. It is easy to operate.

Yifan Zheng — Zhejiang University of Technology

Specification

Dimensions
1370 (w) x 1131 (d) x 1972 (h) mm
The system is on wheels for easy installation and relocation
Weight
1150 kg

Accessories

Smart Manager

Unleash the potential of your data

Until now, instrument data has too often been stuck in manual records, spreadsheets or site-specific servers. By connecting the X'Pert3 to our Smart Manager and continually analyzing instrument data in the cloud, you can unleash its full potential. This is just one of our digital solutions that are part of Malvern Panalytical's Smart Manager.

User manuals

Software downloads

Please contact support for the latest software version.

Support

Solutions to maximize the return on your investment

To assure that your instrument remains in top condition and performs on the highest level, Malvern Panalytical offers a wide range of services. Our expertise and support services assure an optimal functioning of your instrument.

Support

Service for a lifetime

  • Phone and remote support
  • Preventive maintenance and checkups
  • Flexible Customer Care Agreements
  • Performance certificates
  • Hardware and software upgrades
  • Local and global support

Expertise

Adding value to your processes 

  • Sample preparation development/optimization
  • Analytical methodologies 
  • Turnkey solutions for XRD 
  • Operations via IQ/OQ/PQ, quality assurance (GLP, ISO17025) or round robins/inter laboratory studies
  • Consultancy services

Training and education

  • Training on-site or at our competence centers
  • Broad range of basic and advanced courses on products, applications and software

Overview

The long and successful history of Malvern Panalytical's Materials Research Diffractometers (MRD) continues with the generation of X’Pert³ MRD XL. 

The improved performance and reliability of the new platform have added more analytical capability and power for X-ray scattering studies in:

  • advanced materials science
  • scientific and industrial thin film technology
  • metrological characterization in semiconductor process development

The X’Pert³ MRD XL handles a wide range of applications with full wafer mapping up to 200 mm.

Futureproof system flexibility

The X'Pert³ MRD systems offer advanced and innovative X-ray diffraction solutions from research to process development and process control. 

These technologies make all systems field-upgradable to all existing options and new developments in hardware and software to come.

Extended MRD (XL)

The X'Pert³ Extended MRD (XL) brings increased versatility to the range of X'Pert³ MRD systems. An extra PreFIX mounting platform allows mounting of an X-ray mirror and a high-resolution monochromator in-line, significantly increasing the intensity of the incident beam.

You can benefit from increased application versatility without compromise on data quality, high-resolution X-ray diffraction with high intensities, shorter measurement times for measurements such as reciprocal space mapping and rebuild from standard to extended configuration in minutes thanks to the PreFIX concept. With the 2nd generation PreFIX, reconfiguring is easy and optics positioning is more accurate than ever.

MRD (XL) In-plane

With the X'Pert³ MRD (XL) system for in-plane diffraction, it becomes possible to measure diffraction from lattice planes that are perpendicular to the sample surface.

Standard and in-plane geometries on one system and a wide range of diffraction experiments on polycrystalline and highly perfect thin films, are just two of many benefits. 

Download the brochure: Semiconductor wafers - Crystalline quality

Key applications

The Malvern Panalytical X’Pert³ MRD and MRD XL are all-in-one X-ray solution systems that can be used in many industry applications, including:

Semiconductors and single crystal wafers

Whether for growth studies or device design, the measurement of layer quality, thickness, strain and alloy composition using high-resolution XRD has been at the heart of research and development in electronic and optoelectronic multilayer semiconductor devices. With a choice of X-ray mirrors, monochromators and detectors, the X’Pert3 MRD and MRD XL offer high-resolution configurations to suit different materials systems ranging from lattice-matched semiconductors, through relaxed buffer layers on to novel exotic layers on non-standard substrates

Polycrystalline solids and thin films

Polycrystalline layers and coatings are an important component of many thin films and multilayer devices. The evolution of polycrystalline layer morphology during deposition is a key study area in functional materials research and development. X’Pert3 MRD and X’Pert3 MRD XL can be fully equipped with a range of slits, parallel beam X-ray mirror, polycapillary lens, crossed slits and monocapillaries to give the full choice of incident beam optics for reflectometry, stress, texture and phase ID.

Ultra-thin films, nanomaterials and amorphous layers

Functional devices may contain disordered, amorphous or nanocomposite thin films. The flexibility of the X’Pert3 MRD and MRD XL systems allows for the incorporation of multiple analytical methods. A range of high-resolution optics, slits and parallel plate collimators are available to give the optimum performance for grazing incidence methods, in-plane diffraction and reflectometry.

Measurement under non-ambient conditions

Studying the behavior of materials under a variety of conditions is an essential part of materials research and process development. The X’Pert3 MRD and MRD XL are designed for the easy incorporation of the DHS1100 non-ambient sample stage from Anton Paar, enabling automated measurements under a range of temperatures and inert atmosphere

Instrument gives excellent accuracy and is of good quality.Good intensity and rapid performance. It is easy to operate.

Yifan Zheng — Zhejiang University of Technology

Specification

Dimensions
1370 (w) x 1131 (d) x 1972 (h) mm
The system is on wheels for easy installation and relocation
Weight
1150 kg

Accessories

Smart Manager

Unleash the potential of your data

Until now, instrument data has too often been stuck in manual records, spreadsheets or site-specific servers. By connecting the X'Pert3 to our Smart Manager and continually analyzing instrument data in the cloud, you can unleash its full potential. This is just one of our digital solutions that are part of Malvern Panalytical's Smart Manager.

User manuals

Software downloads

Please contact support for the latest software version.

Support

Solutions to maximize the return on your investment

To assure that your instrument remains in top condition and performs on the highest level, Malvern Panalytical offers a wide range of services. Our expertise and support services assure an optimal functioning of your instrument.

Support

Service for a lifetime

  • Phone and remote support
  • Preventive maintenance and checkups
  • Flexible Customer Care Agreements
  • Performance certificates
  • Hardware and software upgrades
  • Local and global support

Expertise

Adding value to your processes 

  • Sample preparation development/optimization
  • Analytical methodologies 
  • Turnkey solutions for XRD 
  • Operations via IQ/OQ/PQ, quality assurance (GLP, ISO17025) or round robins/inter laboratory studies
  • Consultancy services

Training and education

  • Training on-site or at our competence centers
  • Broad range of basic and advanced courses on products, applications and software
The future of thin film analysis.

The future of thin film analysis.

Versatile XRD research & development. High intensities for shorter measurement times. A new generation of tools for your wafer analysis.

Contact sales Request a quote Request a demo