Epsilon 1 for Ultra Low Sulfur (ULS)

Compliant analysis with low running costs

  • Pre-calibrated for analyzing low sulfur content in fuels
  • Analyze as low as 5 ppm sulfur and chlorine
  • No need for helium

Looking for more information?

To request a quote, more information or download a brochure select an option below.


Overview

Epsilon 1 Ultra Low Sulfur is the ideal analytical solution. Pre-calibrated in the factory, our instrument is an out-of-the-box solution for analyzing low sulfur content in fuels. 

Analyses performed are compliant with ISO 13032 and many other sulfur-related international test methods including ASTM D4294, ISO 20847, ISO 8754, IP496, IP336, and JIS K2541-4.

Epsilon 1 ULS gives you precise and accurate data starting at 5 ppm sulfur and chlorine with minimal sample preparation and no need for helium - keeping your total running costs to a minimum.

Robust and flexible quantification

Epsilon 1 is a superior-quality benchtop X-ray fluorescence instrument, pre-calibrated for the analysis of ultra-low sulfur in automotive fuels. 

It provides full compliance with the latest international test methods, including the most stringent: ISO 13032. The results of the repeatability test for sulfur are well within the limits set by this standard. 

Looking to carry out trace analysis of chlorine in crude oils? We provide this as another pre-calibration option for the Epsilon 1 ULS instrument.  

Epsilon 1 ISO - sequence chart.jpg

Features

  • Maximum sensitivity for sulfur and chlorine: The new thin-window vanadium anode X-ray tube, specifically designed and manufactured by Malvern Panalytical, ensures high sensitivity and top-quality measurements. Using vanadium as the anode material is ideal for quantifying sulfur and chlorine without interference from possible line overlaps in the XRF spectrum, leading to more reliable and accurate results. Also, you’ll be happy to know that vanadium and nickel analysis is possible at levels you require to protect your catalysts.

  • No need for helium gas: Epsilon 1 gives you precise and accurate data with minimal sample preparation and running costs. With the high sensitivity of the excitation and detection components, you don’t need helium gas to achieve compliant ISO 13032 results. The air pressure and temperature sensors in the instrument, combined with advanced software algorithms, make sure every measurement result is stable and independent of the environmental conditions. These innovations keep the total running costs to a minimum.

  • Spillage protection: A spillage protection foil is in place to shield the delicate heart of the system. In case of spillage, the foil can be replaced easily by the operator.

  • Easy communication: USB and network connections for standard computer peripherals support extended use, application development, and seated operator.

  • Self-contained system: A built-in computer running Microsoft Windows 10 with a powerful CPU and 120 GB hard drive gives you the flexibility to store and handle thousands of results. The high-resolution, 10.4” LCD touch screen is ideal for easy walk-up operation.

Key applications

The configuration is designed and manufactured for petrochemical applications, specifically for refineries where sulfur and chlorine are critical elements.

Epsilon 1 complies with many sulfur-related international test methods for EDXRF instruments, such as:

  • ISO 13032
  • ASTM D4294
  • ISO 8754
  • ISO 20847
  • IP 336
  • IP 496
  • JIS K2541-4

Specification

Sample loading Highly repeatable sample positioning
Sample size Typical 5 ml liquid
Safety Spillage protection against liquids
Regulatory testing Sulfur analysis in compliance with ISO 13032
Chlorine analysis in crude oils

Accessories

Standards (Reference materials)

CRMs

Claisse is always there to meet your needs!

Claisse provides its customers with quality Certified Reference Materials (CRM) and Reference Materials (RM) from around the world at competitive prices. Whatever your needs, Claisse strives to provide you with the all around services needed to obtain the perfect solution for your XRF, AA and ICP spectroscopy analysis.

Software

Epsilon software

Analytical EDXRF software package for Epsilon benchtop systems

Epsilon software is the XRF analysis software platform that is used with PANalytical’s range of Epsilon 1 and Epsilon 4 benchtop EDXRF systems. The software offers all the functions required to set up and operate an Epsilon benchtop system. The analytical program assembly is greatly facilitated by the high degree of intelligence built into the software, allowing users to benefit from half a century of applications expertise. Daily XRF analysis is a routine task that can be readily carried out by inexperienced personnel after a minimum of instruction. Many features are present to enhance the usability of the software.

Stratos

Determination of composition and thickness of coatings and multi-layers

The Stratos software module features an algorithm which enables simultaneous determination of chemical composition and thickness of layered materials from measurements taken. The software provides a rapid, simple and non-destructive means of analyzing coatings, surface layers and multi-layered structures. The Virtual Analyst provides intelligence during the setup of measurement programs for complicated stacks. 


Available for both the Epsilon 4 EDXRF and Zetium XRF spectrometers, Stratos delivers fast and reliable results regardless of sample type or matrix.

Omnian

Standardless analysis of all types of samples

Omnian enables users to achieve the best possible analysis when dedicated methods or certified standards do not exist. A trendsetting standardless analysis package, Omnian incorporates state-of-the-art software and setup samples that transcend technologies. Available for Epsilon 1, Epsilon 4 and Zetium spectrometers, Omnian delivers fast and reliable results regardless of sample type or matrix.

FingerPrint

Instant material identification

A FingerPrint software module combined with an Epsilon 4 EDXRF system is ideal for material testing when analysis speed is important but the actual composition is not of interest. FingerPrinting generally involves little to no sample preparation and is non-destructive.

Enhanced Data Security

Securing your data and satisfying auditors

The Enhanced Data Security (EDS) module is a software option that provides enhanced trust in results for users of the Zetium XRF spectrometer (through the SuperQ software) and the Epsilon XRF spectrometer. With capabilities including advanced user management, action logging, data protection, and application status assignment, EDS helps you strengthen your audit trail, minimize the risk of error, and prove that your XRF instrument is working as expected.

Sample preparation

Claisse LeNeo

Keeping ahead through Claisse expertise in fusion.

Claisse LeNeo fusion instrument prepares glass disks for XRF as well as borate and peroxide solutions for AA analysis and ICP analysis. LeNeo is a single-position electrical instrument.

More information
Claisse LeNeo

Smart Install

When correctly installed, your new Epsilon 1 will give you reliable analysis results. Installing an Epsilon 1 is straightforward: unpack the system, plug it in and follow the instructions, which we will guide you through. Finally, a simple radiation test completes the installation and confirms that your system is working safely. Yes, it is that easy to start using your Epsilon 1. And, more importantly, you can rest assured that your system is supplied with the necessary safety certification.

Smart install ensures you can get new instruments up and running even when unexpected circumstances or remote locations prevent an engineer from accessing your facility. For the Epsilon 1, we offer a guided  smart installation, enabling you to install the system yourself and maintain the integrity of the instrument and its safety certification.

The advantages of guided smart install:

  • Get up and running fast
  • Save on installation costs
  • Install the system when it suits you
  • Extended 15-month warranty period

Find out more about Smart Install.

User manuals

Software downloads

Please contact support for the latest software version.

Support

Self-support

Take a look at our basic instruction video series to learn more about Epsilon 1:

Services

Solutions to maximize the return on your investment

To assure that your instrument remains in top condition and performs on the highest level, Malvern Panalytical offers a wide range of services. Our expertise and support services assure an optimal functioning of your instrument.

Support

Service for a lifetime

  • Phone and remote support
  • Preventive maintenance and checkups
  • Flexible Customer Care Agreements
  • Performance certificates
  • Hardware and software upgrades
  • Local and global support

Expertise

Adding value to your processes 

  • Sample preparation development/optimization
  • Analytical methodologies 
  • Turnkey solutions for XRD 
  • Operations via IQ/OQ/PQ, quality assurance (GLP, ISO17025) or round robins/inter laboratory studies
  • Automation of lab processes
  • Consultancy services

Training and education

  • Training on-site or at our competence centers
  • Broad range of basic and advanced courses on products, applications and software

Analytical services and calibration materials

  • Expert (XRF) analyses services
  • Oxides and trace analysis
  • Customized calibration materials
Small, powerful, portable XRF.

Small, powerful, portable XRF.

Fully integrated EDXRF analysis. Pre-calibrated for your industry. Ready for fast quantification in the lab - or to take on the road with you.

Contact sales Request a quote Request a demo