Epsilon System Health Evaluator Quick Start Guide
Version number: 1
Take your lab to the sample | Technical guide. Download now
Download now
Looking for more information?
To request a quote, more information or download a brochure select an option below.
Epsilon 1 Ultra Low Sulfur is the ideal analytical solution. Pre-calibrated in the factory, our instrument is an out-of-the-box solution for analyzing low sulfur content in fuels.
Analyses performed are compliant with ISO 13032 and many other sulfur-related international test methods including ASTM D4294, ISO 20847, ISO 8754, IP496, IP336, and JIS K2541-4.
Epsilon 1 ULS gives you precise and accurate data starting at 5 ppm sulfur and chlorine with minimal sample preparation and no need for helium - keeping your total running costs to a minimum.
Epsilon 1 is a superior-quality benchtop X-ray fluorescence instrument, pre-calibrated for the analysis of ultra-low sulfur in automotive fuels.
It provides full compliance with the latest international test methods, including the most stringent: ISO 13032. The results of the repeatability test for sulfur are well within the limits set by this standard.
Looking to carry out trace analysis of chlorine in crude oils? We provide this as another pre-calibration option for the Epsilon 1 ULS instrument.
Maximum sensitivity for sulfur and chlorine: The new thin-window vanadium anode X-ray tube, specifically designed and manufactured by Malvern Panalytical, ensures high sensitivity and top-quality measurements. Using vanadium as the anode material is ideal for quantifying sulfur and chlorine without interference from possible line overlaps in the XRF spectrum, leading to more reliable and accurate results. Also, you’ll be happy to know that vanadium and nickel analysis is possible at levels you require to protect your catalysts.
No need for helium gas: Epsilon 1 gives you precise and accurate data with minimal sample preparation and running costs. With the high sensitivity of the excitation and detection components, you don’t need helium gas to achieve compliant ISO 13032 results. The air pressure and temperature sensors in the instrument, combined with advanced software algorithms, make sure every measurement result is stable and independent of the environmental conditions. These innovations keep the total running costs to a minimum.
Spillage protection: A spillage protection foil is in place to shield the delicate heart of the system. In case of spillage, the foil can be replaced easily by the operator.
Easy communication: USB and network connections for standard computer peripherals support extended use, application development, and seated operator.
Self-contained system: A built-in computer running Microsoft Windows 10 with a powerful CPU and 120 GB hard drive gives you the flexibility to store and handle thousands of results. The high-resolution, 10.4” LCD touch screen is ideal for easy walk-up operation.
The configuration is designed and manufactured for petrochemical applications, specifically for refineries where sulfur and chlorine are critical elements.
Epsilon 1 complies with many sulfur-related international test methods for EDXRF instruments, such as:
| Sample loading | Highly repeatable sample positioning |
|---|---|
| Sample size | Typical 5 ml liquid |
| Safety | Spillage protection against liquids |
| Regulatory testing | Sulfur analysis in compliance with ISO 13032
Chlorine analysis in crude oils |
| Features | High-stability ceramic side window
50 micrometer thin window (Be) Vanadium anode, ideal for sulfur and chlorine analysis |
|---|---|
| Power | Software-controlled, max voltage 30 kV |
| Resolution | High-resolution, typical 135 eV |
|---|---|
| Features | 8 micrometer thin window (Be)
High count-rate capacity |
| Software | Optional, depending on requirements, for example:
|
|---|---|
| Interface | Operator mode with big buttons for easy operation
Advanced mode with many features
|
When correctly installed, your new Epsilon 1 will give you reliable analysis results. Installing an Epsilon 1 is straightforward: unpack the system, plug it in and follow the instructions, which we will guide you through. Finally, a simple radiation test completes the installation and confirms that your system is working safely. Yes, it is that easy to start using your Epsilon 1. And, more importantly, you can rest assured that your system is supplied with the necessary safety certification.
Smart install ensures you can get new instruments up and running even when unexpected circumstances or remote locations prevent an engineer from accessing your facility. For the Epsilon 1, we offer a guided smart installation, enabling you to install the system yourself and maintain the integrity of the instrument and its safety certification.
The advantages of guided smart install:
Find out more about Smart Install.
Version number: 1
Version number: 5
Please contact support for the latest software version.
Take a look at our basic instruction video series to learn more about Epsilon 1:
To assure that your instrument remains in top condition and performs on the highest level, Malvern Panalytical offers a wide range of services. Our expertise and support services assure an optimal functioning of your instrument.
Service for a lifetime
Adding value to your processes
Epsilon 1 Ultra Low Sulfur is the ideal analytical solution. Pre-calibrated in the factory, our instrument is an out-of-the-box solution for analyzing low sulfur content in fuels.
Analyses performed are compliant with ISO 13032 and many other sulfur-related international test methods including ASTM D4294, ISO 20847, ISO 8754, IP496, IP336, and JIS K2541-4.
Epsilon 1 ULS gives you precise and accurate data starting at 5 ppm sulfur and chlorine with minimal sample preparation and no need for helium - keeping your total running costs to a minimum.
Epsilon 1 is a superior-quality benchtop X-ray fluorescence instrument, pre-calibrated for the analysis of ultra-low sulfur in automotive fuels.
It provides full compliance with the latest international test methods, including the most stringent: ISO 13032. The results of the repeatability test for sulfur are well within the limits set by this standard.
Looking to carry out trace analysis of chlorine in crude oils? We provide this as another pre-calibration option for the Epsilon 1 ULS instrument.
Maximum sensitivity for sulfur and chlorine: The new thin-window vanadium anode X-ray tube, specifically designed and manufactured by Malvern Panalytical, ensures high sensitivity and top-quality measurements. Using vanadium as the anode material is ideal for quantifying sulfur and chlorine without interference from possible line overlaps in the XRF spectrum, leading to more reliable and accurate results. Also, you’ll be happy to know that vanadium and nickel analysis is possible at levels you require to protect your catalysts.
No need for helium gas: Epsilon 1 gives you precise and accurate data with minimal sample preparation and running costs. With the high sensitivity of the excitation and detection components, you don’t need helium gas to achieve compliant ISO 13032 results. The air pressure and temperature sensors in the instrument, combined with advanced software algorithms, make sure every measurement result is stable and independent of the environmental conditions. These innovations keep the total running costs to a minimum.
Spillage protection: A spillage protection foil is in place to shield the delicate heart of the system. In case of spillage, the foil can be replaced easily by the operator.
Easy communication: USB and network connections for standard computer peripherals support extended use, application development, and seated operator.
Self-contained system: A built-in computer running Microsoft Windows 10 with a powerful CPU and 120 GB hard drive gives you the flexibility to store and handle thousands of results. The high-resolution, 10.4” LCD touch screen is ideal for easy walk-up operation.
The configuration is designed and manufactured for petrochemical applications, specifically for refineries where sulfur and chlorine are critical elements.
Epsilon 1 complies with many sulfur-related international test methods for EDXRF instruments, such as:
| Sample loading | Highly repeatable sample positioning |
|---|---|
| Sample size | Typical 5 ml liquid |
| Safety | Spillage protection against liquids |
| Regulatory testing | Sulfur analysis in compliance with ISO 13032
Chlorine analysis in crude oils |
| Features | High-stability ceramic side window
50 micrometer thin window (Be) Vanadium anode, ideal for sulfur and chlorine analysis |
|---|---|
| Power | Software-controlled, max voltage 30 kV |
| Resolution | High-resolution, typical 135 eV |
|---|---|
| Features | 8 micrometer thin window (Be)
High count-rate capacity |
| Software | Optional, depending on requirements, for example:
|
|---|---|
| Interface | Operator mode with big buttons for easy operation
Advanced mode with many features
|
When correctly installed, your new Epsilon 1 will give you reliable analysis results. Installing an Epsilon 1 is straightforward: unpack the system, plug it in and follow the instructions, which we will guide you through. Finally, a simple radiation test completes the installation and confirms that your system is working safely. Yes, it is that easy to start using your Epsilon 1. And, more importantly, you can rest assured that your system is supplied with the necessary safety certification.
Smart install ensures you can get new instruments up and running even when unexpected circumstances or remote locations prevent an engineer from accessing your facility. For the Epsilon 1, we offer a guided smart installation, enabling you to install the system yourself and maintain the integrity of the instrument and its safety certification.
The advantages of guided smart install:
Find out more about Smart Install.
Version number: 1
Version number: 5
Please contact support for the latest software version.
Take a look at our basic instruction video series to learn more about Epsilon 1:
To assure that your instrument remains in top condition and performs on the highest level, Malvern Panalytical offers a wide range of services. Our expertise and support services assure an optimal functioning of your instrument.
Service for a lifetime
Adding value to your processes
Fully integrated EDXRF analysis. Pre-calibrated for your industry. Ready for fast quantification in the lab - or to take on the road with you.